22
10. Summary table of thermostat parameters
Function
Parameters
Value range
Reso-
lution
Default value
Multi-function input
IN selection
[Off, Nighttime
Reduction,
Activation,
Heating/Air-Con.]
-
Off
Nighttime Reduction
δ
R
(red. offset)
[1,..,6]°C
0.1°C
4°C
Temperature control mode
Selection
TempCtrl
[Heat., Air-con.]
-
Heating
Control algorithm
Algorithm
[ON/OFF, PID]
-
ON/OFF
Hysteresis (ON/OFF)
δ
T
(Differential)
[0.1,..,1]°C
0.1°C
0.2°C
Proportional band (PID)
Band
[0.5,..,5]°C
0.1°C
1°C
Adjustment period (PID)
Period
[10,..,30] minutes
1 min
20 min
Unit of measurement (tem-
perature)
Temperature unit
[°C , °F]
-
°C
Temperature offset
T
E
(Offset temp.)
[0,..,±3]°C
0.1°C
0°C
Adjustment limit range
Offset (
δ
U
)
[0,..,2]°C
0°C
0.5°C
PIN number
PIN
[000,..,999]
1
000
Temperature set-point
T
0
(Away-Heat.)
[TG, 10..35]°C
0.1°C
16°C
T
2
(Comfort-Heat.)
[10,..,35]°C
0.1°C
20°C
T
0
(Away-Aircon.)
[10,..,35,OFF]°C
0.1°C
29°C
T
2
(Comfort-Aircon.)
[10,..,35]°C
0.1°C
25°C
T
M
(Manual-Heat.)
[10,..,35]°C
0.1°C
18°C
T
M
(Manual-Aircon.)
[10,..,35]°C
0.1°C
26°C
T
G
(Antifreeze)
[4,..,10]°C
0.1°C
5°C
Reset to default parameters
rSEt
-
-
-
Table 1: Device parameters
Summary of Contents for 2905