background image

21

7.5  Alternative views

During normal operation, i.e. when you are not navigating the menus, you can select the information to 
display on the left-hand side of the display. 

Fig. 16: Typical view of the time and daily program

This view is the default and gives an indication of the daily temperature control program along with the 
data on the current moment. 
T

he program area

, represented by histograms, is divided into 24 sectors each of which represents the 

corresponding hour of the 24 hours in a day.

Each sector can be composed of 1, 2 or 3 dashes:
   

equivalent to “T away” ( 

 )

   

equivalent to “T economy” ( 

 )  

   

equivalent to “T comfort” ( 

 )

T

he clock

 shows the current time. 

T

he indicator of the day of the week

 highlights the current day with a dash under the number associ-

ated with it (eg, 4 = Thursday).  
T

he set temperature indicator

 highlights the current temperature being regulated thus replicating the 

information represented by the “dashes”:

 

= T away

 

= T economy 

 

= T comfort

T

he energy saving indicator

 indicates whether, compared to a conventional average consumption, the 

set temperature setpoint enables you to achieve "savings" in consumption. 

If the operating mode is not set on 

AUTO

, the program area will not be active.

Indicatore qualità segnale WiFi

Energy saving indicator

Clock

Day of the week indicator

Set temperature indicator

Daily program

Summary of Contents for 2911

Page 1: ...Instructions manual 02911 WiFi Timer Thermostat Installer Manual ...

Page 2: ......

Page 3: ...tings menu 27 9 1 Operating mode setting 28 9 2 Setting the time and day of the week 28 9 3 Heating air conditioning setting 28 9 4 Temperature setting 29 9 5 Daily program setting 29 9 6 Unit of measurement setting 30 9 7 Calibration setting 32 9 8 External probe setting 32 9 9 OnOff PID temperature control algorithm setting 33 9 10 Buzzer beep setting 33 9 11 Standby brightness level setting 34 ...

Page 4: ...g between the device and the authorized applications for the remote control function as well as signals for verifying correct access and operation of these services and devic es The above information is all necessary and functional in order to enable correctly performing the functions of remote control and maintenance of the applications and devices supported by the platform The ID of the device a...

Page 5: ...burner or circu lation pump heating or on the control circuit of the air conditioner air conditioning ensuring an ideal temperature The graphical user interface thanks to special views facilitates system management helping the user to oper ate while maintaining a state of energy saving 3 Installation The appliance must be installed on a wall at a height of 1 5 m off the floor in a suitable positio...

Page 6: ...R SpA MADE IN ITALY 02906 T40 5 2 A 230V 230V 50 60Hz 1 C C N L NC NO 6 mm V I M A R SpA MADE IN ITALY 02906 T40 5 2 A 230V 230V 50 60Hz 1 C C N L NC NO 6 mm V I M A R SpA e2 Pb 3 4 5 6 V I M A R SpA MADE IN ITA LY 02906 T40 5 2 A 230V 230V 50 60Hz 1 C C N L NC NO 6 mm 2 click 1 7 ...

Page 7: ...65 N T C V I M A R SpA e2 Pb C NCNO N L Fig 1 Circulation pumps burners solenoid valves L N art 02965 N T C U1 V I M A R SpA e2 Pb C NCNO N L CHIUDE CLOSES FERMÉE SCHLIESSEN CERRAR ΚΛΕΙΣΙΜΟ APRE OPENS OUVERTE ÖFFNEN ABRIR ΑΝΟΙΓΜΑ Fig 2 Motorized valves ...

Page 8: ...res in the 2 terminals without any particular order It is recommended to use the NTC 10k beta 3900 probe art 02965 20432 19432 14432 The typical wiring diagram is the following art 02965 N T C V I M A R S p A e2 Pb C NCNO N L V I M A R SpA e2 Pb C NCNO N L art 20432 art 19432 art 14432 Fig 3 Connecting the external temperature probe 4 2 1 Installation examples 02695 used to display the outside tem...

Page 9: ...95 used for limiting the temperature of underfloor heating IMPORTANT During installation take care not to damage the insulation of the probe while laying the screed Perform the installation in such a way that the probe is accessible for any maintenance work ...

Page 10: ...pears on the display where you can reset the device parameters Fig 5 Parameter reset screen By confirming with ALL the device parameters temperature setpoint heating air conditioning mode unit of measurement etc and ALL WiFi function settings phone numbers SMS etc will be restored to the default values WARNING This operation is not undoable If you wish to reset only the GSM settings refer to parag...

Page 11: ...te of installation make sure the Gateway Router has been turned on for at least 2 minutes and is connected to the Internet Make sure the timer thermostat is installed at a reasonable distance from the router where the signal is strong enough Activate configuration mode in this phase the timer thermostat acts as an access point generating a specific temporary WiFi network for the configuration with...

Page 12: ...e OnOF menu by tapping ON or OFF will begin to flash Using and select ON and confirm by tapping 5 Using and scroll through the list of options until you see the Conf screen 6 Confirm by touching 7 The display will show Strt ...

Page 13: ...ptions a tapping b closing the By clima App c when the mobile device e g smartphone goes into standby 6 1 2 Configuring the timer thermostat with the By clima App Pick up the mobile device on which is installed the By clima App updated to the latest version Stand in front of the timer thermostat On the device enable the WiFi interface and scan for available networks Connect the mobile device to th...

Page 14: ...ring VIMAR02911 and a variable portion of 6 hexadecimal characters indicating the serial number of the device you want to configure see the example in figures 6 and 7 1 Launch the By clima App on the mobile device 2 Add a new device by tapping Fig 6 Back of the timer thermostat 02911 Fig 7 Network selection screen on smartphone ...

Page 15: ...one vuoi effettuare Sostituire un CronoTermostato Configurare un nuovo CronoTermostato Collegarsi ad un CronoTermostato attivo SC02 1 Giovedì 19 Dicembre 2013 Casa I tuoi dispositivi ungi un dispositivo Scegli un modello 02955 ClimaChrono Cronotermostato RGB da incasso 01913 ClimaChrono Cronotermostato GSM da parete 02911 ChronoWiFi Cronotermostato Wi fi da parete 02906 ClimaTermo Termostato touch G...

Page 16: ...tions displayed directly by the App Scegli un modello 02955 ClimaChrono Cronotermostato RGB da incasso 01913 ClimaChrono Cronotermostato GSM da parete 02911 ChronoWiFi Cronotermostato Wi fi da parete 02906 ClimaTermo Termostato touch GSM da parete Quale operazione vuoi effettuare Sostituire un CronoTermostato Configurare un nuovo CronoTermostato Collegarsi ad un CronoTermostato attivo C Giovedì 19 D...

Page 17: ...ng the WiFi network and cloud services The network parameters should be configured during initial installation and or if you change the network cre dentials with which the timer thermostat connects to your home WiFi Using the By clima App you enter the section shown in the figure on the next page and proceed by entering the parameters with which the timer thermostat will connect to your home WiFi ...

Page 18: ...ermostat software Saving all the timer thermostat settings should you need to replace it Registration with the Vimar cloud is automatic and is linked to the timer thermostat creating a user is not required no login By pairing a mobile device with the timer thermostat the smartphone tablet is merged at the logic level with the registration of the timer thermostat in the cloud see par 6 2 6 3 2 Use ...

Page 19: ...be controlled if the mobile device is paired with the timer thermostat the PIN code of the mobile device and that of the timer thermostat coincide If you change the PIN of the timer thermostat but not that of the tablet smartphone the mobile device which is still set to the old PIN will no longer be able to manage the timer thermostat it will then be necessary to update the PIN of the tablet smart...

Page 20: ... using the following buttons and icons Fig 14 Graphical interface and buttons A WiFi radio signal strength indicator B Operating mode C Away D Confirm E F Menu navigation and setting parameters G Back H Settings menu I AUTO programme temperature trends I H G F E D C B A ...

Page 21: ...d option activates the submenu if there is one or displays the next parameter digit After each confirmation the display shows the icon for approximately 1 s back or cancel exits the current screen menu and returns to the previous one without saving any changes In menus with changes to multiple digits it lets you go back to change the previous digit N B The field value being edited is highlighted b...

Page 22: ...el of the device 7 4 Locking the interface via PIN The timer thermostat lets you set a password which inhibits any change to the operating mode eg switching from Manual to OFF limits setting the temperature values and more generally blocks access to the configuration menu This feature is useful to prevent the thermostat being used by unauthorized persons the device prompts you to enter the PIN ind...

Page 23: ...o T away equivalent to T economy equivalent to T comfort The clock shows the current time The indicator of the day of the week highlights the current day with a dash under the number associ ated with it eg 4 Thursday The set temperature indicator highlights the current temperature being regulated thus replicating the information represented by the dashes T away T economy T comfort The energy savin...

Page 24: ...for any period of time at the end of which the device will return to AUTO mode Away lets you set the set point in order to achieve significant energy savings during periods when the user is away Antifreeze used to set a minimum temperature level to avoid damage to pipework or prevent the temper ature from falling below a safety level The operating mode is selected via the SETTINGS menu or with the...

Page 25: ...active the icon is displayed above the temperature indicator Fig 18 Typical screen for Manual mode The set point can always be changed via or Fig 19 Manual set point setting The selection is confirmed by touching The and icons in the lower right corner indicate whether the system is operating in heating or air conditioning mode respectively icon illuminated system on ...

Page 26: ... mode By touching and you can temporarily change the ambient temperature setting it to a differ ent value to the one associated with the current time slot Confirming with it then goes into TIMED MANUAL mode The and icons in the lower right corner indicate whether the system is operating in heating or air conditioning mode respectively icon illuminated system on 8 4 Timed manual This mode allows yo...

Page 27: ...e next screen again using and lets you set the time for which the temperature you have just set is maintained Fig 22 Regulating the number of hours of Timed Manual mode Finally confirm with At the end of the set time the timer thermostat goes back into AUTO mode the icon switches off and reappears ...

Page 28: ...he adjustment according to the away temperature setpoint The Away mode can only be activated by touching The display will show the away temperature setpoint for approximately 2 seconds Fig 23 Input in away mode showing the away temperature Mode activation is identified by the icon Fig 24 Away Mode To exit and return to the initial mode touch the button again ...

Page 29: ...e activated antifreeze mode is identified by the icon above the temperature indicator Fig 25 Antifreeze mode 9 Settings menu From the settings menu you can configure all the features of the timer thermostat On the main screen tap the icon From the main menu using and will display the following flashing symbols in succession which provide access to the corresponding submenus 1 operating mode settin...

Page 30: ...the operating mode of the device Manual Automatic Off Antifreeze only if the thermostat is set on heating Using and select the desired mode and confirm with 9 2 Setting the time and day of the week This menu lets you set the time and day of the week Using and set the hour confirm with and similarly set the minutes and then the day of the week The days of the week are represented by numbers from 1 ...

Page 31: ...ets you increase decrease the value of the away temperature and The away temperature is an intermediate temperature geared to obtain substantial energy savings during periods when the user is away The away temperature differs depending on whether you are in the heating or air conditioning mode 9 4 1 Economy temperature The menu via and lets you increase decrease the value of the economy temper atu...

Page 32: ...increase decrease the value of the antifreeze temper ature and Antifreeze mode is used to set a minimum temperature level to avoid damage to the pipework or keep the room temperature from falling below a safety level 9 5 Daily program setting This menu lets you set or modify the time and daily program for the ambient temperature The program lets you associate each quarter hour of the day and in a ...

Page 33: ...or all of the next quarter of an hour On touching the temperature selected for the current time is assigned to the next quarter of an hour too in this case the temperature symbol is the same but the current time shown by the clock is moved forward by 15 minutes Using and you can move respectively between the hours of the day and move forwards or backwards 15 minutes at a time During the movement a...

Page 34: ...nfigure how to use the external temperature probe installed according to the instructions in par 4 2 Using or you can select the following options OFF the external probe although physically present is ignored by the device Adjustment the measured temperature flashes by enabling this function the thermostat will regulate the temperature of the environment based ONLY on the temperature detected by t...

Page 35: ...y calibrated according to the type of envi ronment and heating system in the light of this the following parameters must be set via the submenus that follow this selection breadth of adjustment range starting from the set temperature Tb is the temperature range in which the heating power goes from 0 to 100 For example with the temperature for heating set to 20 0 C and Tb 4 0 C the thermostat acti ...

Page 36: ...tage of the cloud service offered by Vimar If you do not intend to use this service some of the following submenus will be inhibited Using and select ON or OFF to use or not use the cloud service and confirm with 9 12 3 Automatic time synchronization The menu enables automatic synchronization of the clock directly from the cloud Using and select ON or OFF to enable or disable clock synchronization...

Page 37: ... WiFi Info 9 12 6 1 WiFi FW version The menu lets you view the version of the firmware for the WiFi interface It should be used if required when seeking support Touch to display the FW version 9 12 6 2 Statistics The menu lets you view the device statistics ie its error codes It should be used if required when seeking support Touch to display the statistics 9 12 6 3 FWuP This is an advanced menu w...

Page 38: ... off the device nor access the timer thermostat with the By clima app 9 14 Lock unlock PIN setting This menu lets you add change the password to inhibit use of the timer thermostat Using and set the three digits of the PIN one at a time and then confirm each set digit with If you wish to have free access to the thermostat so without it prompting you for a password it is suf ficient to set the PIN ...

Page 39: ...20 C T0 Away Aircon 10 35 OFF C 0 1 C 29 C T1 Economy Aircon 10 35 C 0 1 C 27 C T2 Comfort Aircon 10 35 C 0 1 C 25 C TM Manual Heat 10 35 C 0 1 C 18 C TM Manual Aircon 10 35 C 0 1 C 26 C TG Antifreeze 4 10 C 0 1 C 5 C Programs Heating Prog T0 T1 T2 Heating for each interval of time 24hx4x7d Air Con Prog T0 T1 T2 Air con for each interval of time 24hx4x7d WiFi Radio On ON OFF ON Cloud Enable cloud ...

Page 40: ...timer thermostat Parameters Functionality Value range Enable under temperature over temperature alarm Enables monitoring and thus potentially generating the corresponding alarms OFF ON Temperature control probe lower temperature threshold Threshold that when crossed generates a tem perature control probe under temperature alarm notification 0 40 C Temperature control probe upper temperature thresh...

Page 41: ...tworks requiring dynam ic exchange of authentication certificates or ones that in any case require registration login via a Web Browser 2 The WiFi timer thermostat supports access to WiFi networks with WEP encryption with the following limitations a 64 or 128 bit WEP with a 10 or 26 character key in hexadecimal format not ASCII b WEP with Open key Open c WEP with shared key Shared NOT supported 3 ...

Page 42: ...for accessing a password based WiFi network recommended WEP security system for accessing an old type of WiFi network not recommended if you have a router with this type of security system you should modify it with WPA or WPA2 See paragraph 11 note 2 IP communication protocol on which the entire Internet network is based IP Address the address that every device must have in order to communicate wi...

Page 43: ...17 1 WiFi Timer Thermostat Serial number 17 2 WiFi Router Main router of the installation site Brand Model Notes 17 3 Additional Access Point If there is an additional device that extends the WiFi coverage inside the home site Brand Model Notes ...

Page 44: ...02911 installatore EN 01 1501 VIMAR Marostica Italy Viale Vicenza 14 36063 Marostica VI Italy Tel 39 0424 488 600 Fax Italia 39 0424 488 188 Fax Export 39 0424 488 709 www vimar com ...

Reviews: