POINT B - SETTINGS
DIP 1 (ON)
BARRIER SLOWSPEEDS ADJUSTMENT IN OPENING AND
CLOSING (ON) (See Point C)
DIP 1-2
STORING/ERASING RADIO CODES FOR MOTOR CONTROL (See
Point D)
DIP SWITCHES CONTROL
DIP 4 Single impulse command START and RADIO - step-by-step (ON) - automatic (OFF)
DIP 5 - (not used)
DIP 6 NORMAL operation (OFF) - PARK operation (ON)
DIP 7
ON - photocells self-test ENABLED
DIP 8 OPEN 2 command operation in PARK mode
ON - OPEN 2 command is always enabled
OFF - OPEN 2 command works if there is no vehicle on the magnetic sensor
connected to the TLC input (Traffic light control contact opened).
DIP 9
OFF
DIP 10
Operation after black-out
ON - the boom arm automatically closes if not already closed.
OFF - the boom arm remains still on the point it was when blackout occurred
DIP 11
OFF - 1-phase motor
DIP 12
OFF - Electromechanical limit switches welded on pc card
DIP 13
ON - Lamp with flashing light / OFF - Blinker operation with fixed power supply
BARRIER CODE
DIP 14 DIP 15 D I P
16
EBR1
with 3m boom arm
OFF
OFF
OFF
EBR1
with 4m boom arm
ON
OFF
OFF
EBR2
with 5m boom arm
OFF
ON
OFF
EBR2
with 6m boom arm
ON
ON
OFF
LED WARNINGS
DL1
PROG programming activated
(red)
DL2
Barrier opening
(green)
DL3
Barrier closing
(red)
DL4
Opening limit switch LSO
(green)
DL5
Closing limit switch LSC
(red)
DL6
STOP command (NC)
(red)
DL7
PHOTO 1 contact (NC)
(red)
DL8
PHOTO 2 contact (NC)
(red)
DL9
EDGE 1 contact (NC)
(red)
DL10
PROG command
(green)
DL11
TCA - automatic closure time enabled
(red)
DL12
Remotes programming enabled
(two colors)
DL13
- (not used)
(blue)
OPEN 1
OPEN 1 command (to enter)
(green)
OPEN 2
OPEN 2 command (to exit)
(green)
CLOSE
CLOSE command (NO)
(green)
START
Single impulse command (NO)
(green)
B.I.O
Clock command (NO)
(green)
OK CLOSE Confirmation of closing command
(green)
TLC
Magnetic sensor control for traffic light control
(green)
ADJUSTMENTS
TRIMMER LOW SPEED OPEN and TRIMMER LOW SPEED CLOSE - Slow speed
regulators in opening and closing approach
Slow speed regulation is performed by acting on the LOW SPEED OPEN and LOW
SPEED CLOSE trimmers through which the output voltage across the motor is varied
(turning it clockwise increases the speed).
The deceleration is automatically determined by the limit switches at about 30° before
reaching the opening or closing limit switch.
TRIMMER TCA - Automatic closing time regulator
standard not enabled and LED DL11 OFF
(trimmer rotated completely counter-clockwise)
With this trimmer it is possible to adjust the waiting time before having automatic closing.
The automatic closing is obtained only with the barrier open as a result of the command
given by the opening commands and led DL11 ON (trimmer rotated clockwise to enable
the feature).
The pause time can be adjusted from a minimum of 2 seconds to a maximum of 2
minutes.
R-AUX - AUXILIARY RELAY CONTACT (NO)
By default this relay is set as courtesy light (max 700 W - 3 A - 230 Vac) to operate 3
minutes at each command, with time renewal at each command.
POINT C - BARRIER SLOWSPEEDS ADJUSTMENT IN OPENING AND CLOSING
This check is meant to facilitate the installer during the start-up of the system or for any
other future controls:
1 -
Turn DIP1 to ON
, the red led DL1 starts blinking
2 -
Press the PROG button
and hold it (movement is now performed in “hold-to-run”
mode, open-stop-close-stop-open etc.). If the GREEN led DL2 is on, the boom arm
opens. If the RED led DL4 is on, the boom arm closes.
3 -
Carry out the slow-down speed calibration => Turn the LOW SPEED OPEN and
LOW SPEED CLOSE trimmer to minimum =>
Press the PROG button
and hold it
=> After 1 second of movement the low speed will be enabled.
CAUTION
: Check that the motor has enough force to move the boom both in opening
and closing. If not, increase the value set on the trimmers until the optimal
operating condition is reached.
CAUTION
: In areas subject to particularly cold temperatures, turn the trimmers
clockwise 5° more than the normal value, or apply the optional probe (code
ACG4666) to heat the engine.
4 -
Turn DIP1 to OFF
=> the red LED DL1 turns off.
During Point C procedure the safety-strip and photocells are not enabled.
POINT D - PROGRAMMING RADIO CODES FOR OPENING (1000 CODES MAX)
Only the 433MHz rolling code transmitters can be memorized:
ETRN2 2-channel transmitter
ETRN4 4-channel transmitter
ETR5 2-channel transmitter
ETR4 4-channel transmitter
Programming can be done only when the gate is stationary.
1 - First set DIP 1 to ON and then DIP 2 to ON. The LED DL12 flashes red for 10
seconds.
2 - Press the TRANSMITTER button (usually channel A) within the allotted 10 seconds.
If the remote is memorized properly LED DL12 blinks green and a buzzer tone
confirms the correct memorization. The 10 seconds for programming the codes are
automatically renewed, with LED DL12 which flashes red, in order to store the next
transmitter.
3 - To finish programming, wait 10 seconds, or press the PROG button briefly. LED
DL12 stops flashing.
4 - Re-set DIP 1 to OFF and DIP 2 to OFF.
5 - End of procedure.
ALL RADIO CODES FOR TOTAL OPENING CANCELLATION PROCEDURE
Cancellations can only be performed when gate is stationary.
1 - Set DIP 1 to ON and then DIP 2 to ON.
2 - LED DL12 flashes red for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. Memory cancellation is indicated by
two green flashes of LED DL12 and 2 tones of the buzzer.
4 - LED DL12 flashes red again for 10 seonds and you can add new codes as shown
above.
5 - Re-set DIP 1 to OFF and DIP 2 to OFF.
6 - End of procedure.
RADIO CODES MEMORY FULL INDICATOR (FOR TOTAL OPENING)
Indication is visible only when gate is stationary.
1 - Set DIP 1 to ON and then DIP 2 to ON.
2 - The LED DL12 flashes green 6 times when the memory is full (1000 codes). Now
LED DL12 blinks red for 10 seconds enabling possible cancellation of all codes.
3 - Re-set DIP 1 to OFF and DIP 2 to OFF.
4 - End of procedure.
24
FRAGMA