TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
EVENT
BUZZER STATUS
FLASHER STATUS
DL1 LED STATUS
Dip 1 ON (hold-to-run mode)
Or failure of a safety device
Off
Off
Flashes on-off 250 ms
Dip 2 ON (stroke programming)
Off
Off
Flashes on-off 500 ms
Programming sequence stopped due to intervention of a
safety device
10 seconds tone with 2 seconds
pause
Off
On steady
EVENT
BUZZER STATUS
FLASHER STATUS
DL12 LED STATUS
No transmitter code entered
Off
Off
Flashes intermittently red/green
Dip 1 > 2 - transmitter code programming for full opening
Off
Off
Flashes red for 10 seconds
Correct transmitter codes programming for opening
1 Tone
Off
Turns green once
Remote control code not present in memory
Off
Off
Turns red once
Memory saturated by remote control codes (1000 codes
saved)
Off
Off
Runs 6 green flashes
Radio code deletion for opening
2 Tones
Off
Runs 2 green flashes
WARNING SIGNALS DURING OPERATION
EVENT
BUZZER STATUS
FLASHER STATUS
LED STATUS AND SIGNAL OUTPUT
Stop button pressed
Off
Off
Led DL6 turns off
Photocell intervention
1 Tone
Off
Led DL7-8 turns off
Edge intervention
2 Tones
Off
Led DL9 turns off
Failure of a safety device or safety device engaged for too
long
Off
Off
Led DL1 flashes on-off 250 ms
Alarm from edge
2 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
Enabled for 1 minute No led combined
Failed photocells auto-test alarm
4 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
Off
No led combined
Alarm - no limit switches reached or unlocked barrier
5 Tones
Enabled for 1 minute No leds matched
FAULT
SOLUTION
After having carried out the various connections and having supplied voltage, all the
LEDS are switched off.
On the board there are resettable fuses which intervene in the event of a short
circuit, interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable
connectors and insert them one at a time in order to more easily identify the
cause of the fault.
Check the integrity of fuse F1.
In case of interrupted fuse use only of adequate value
F1 = T 5A Fuse for motor protection
The motor opens and closes, but it has no strength and moves slowly.
Check trimmers TORQUE, LOW SPEED OPEN and LOW SPEED CLOSE
adjustment.
The gate opens but does not close after the time set.
Make sure that the TCA trimmer is activated with LED DL11 ON.
B.I.O. contact always on / green led on => check the status of the clock connected to
B.I.O. input.
Photocells Auto-test failed => check the connections between the control panel and
the photocells.
The gate does not close by activating the various START, RADIO and CLOSE buttons. Faulty safety edge contact. Faulty photocells contact => Fix or replace the faulty
contact.
Photocells Auto-test failed => check the connections between the control panel and
the photocells.
By activating the START, OPEN or CLOSE button the barrier does not move.
START, OPEN or CLOSE command always active.
Check and replace any buttons or micro-switches of the selector switch.
The slowing phase is not performed.
Check LOW SPEED OPEN e LOW SPEED CLOSE trimmers adjustment.
Declaration of Conformity.
Vimar SpA declares that the equipment complies with Directives:
2014/53/EU (RED)
2014/30/EU (EMC)
2014/35/EU (LVD)
2006/42/CE (Machinery Directive)
The full text of the EU declaration of conformity is on the product sheet available at the following Internet address: www.vimar.com.
REACH (EU) Regulation no. 1907/2006 – Art.33.
The product may contain traces of lead.