14 - ENGLISH
3. INSTALLATION.
The appliance must be installed in flush or surface mounting boxes
with EIKON frames and plates at a height of 1 .5 m off the floor in
a suitable position for correctly detecting the ambient temperature .
It must not be installed in niches, behind doors and curtains or in
areas affected by sources of heat or atmospheric factors .
In par-
ticular, it must not be installed on outer walls or in association
with appliances that generate heat (e.g. dimmers or lamps).
It should be used in dry, dust-free places at a temperature between
0 °C and +40 °C .
1. DESCRIPTION.
Electronic thermostat for temperature control in the residential sector
(heating and air conditioning) . Input terminals for temperature reduc-
tion and for switching on with a phone dial .
6(2) A 230 V~ change-over relay output, power supply 120-230 V~
50-60 Hz - 2 modules .
2. FIELD OF APPLICATION.
The appliance is designed to control room temperature by acting on
the control circuit of the burner or circulation pump (heating) or on
the control circuit of the air conditioner (air conditioning) .
The large display shows the room temperature, system operating
status and mode (summer, winter, reduction) .
All the parameters are programmed with the 4 buttons on the front
of the appliance .
Summary of Contents for Eikon 20440
Page 2: ......
Page 4: ......
Page 9: ...ITALIANO 5 5 COLLEGAMENTI 5 1 Schemi di collegamento L N U1 L N U1 APRE CHIUDE ...
Page 16: ......
Page 21: ...ENGLISH 17 5 CONNECTIONS 5 1 Connection diagrams L N U1 L N U1 OPEN CLOSE ...
Page 28: ......
Page 33: ...FRANÇAIS 29 5 RACCORDEMENTS 5 1 Schémas de raccordement L N U1 L N U1 OUVERT FERME ...
Page 40: ......
Page 45: ...DEUTSCH 41 5 ANSCHLÜSSE 5 1 Anschlussplan L N U1 L N U1 SCHLIESSEN ÖFFNEN ...
Page 52: ......
Page 57: ...ESPAÑOL 53 5 CONEXIONES 5 1 Esquemas de conexión L N U1 L N U1 ABIERTO CERRADO ...
Page 64: ......
Page 69: ...ΕΛΛΗΝΙΚА 65 5 ΣΥΝΔΕΣΕΙΣ 5 1 Σχεδιαγράμματα σύνδεσης L N U1 L N U1 ΑΝΟΙΓΑ ΚΑΕΙΣΙΜΟ ...