17

KLYS

EN

Maximum door height

Operator

Maximum door surface 

area

Track length

Track

Sectional 

(fig. 4a)

Up-and-over door with 

spring (fig. 4b)

Up-and-over door with 

counterweights (fig. 4c)

ENM1 (KLYS 9SD)

9 m

2

3 m

ENX1/ENX2 2.5

2.4

2.4

4 m

ENX3

3.5

3

ENM2 (KLYS 12SD) 12 m

2

3 m

ENX4

2.5

2.4

2.4

4 m

ENX5

3.5

3

4. Standard system set-up:

Before installing the automation, check that:

the hinges, bearings and door guides are strong and there is no excessive friction between the fixed and moving parts, that the mechanical stops are well fixed 

on opening, that the door is correctly balanced there is a space of at least 40 mm from the highest point of the door to the ceiling (fig. 3); make sure that the 

door is ready for mounting the motorisation (the upper wheel of the last panel must be in a horizontal and not vertical stretch of the guide as shown in fig. 3)

For the system wiring arrangements, refer to fig. 1.

5. Mechanical installation on sectional door:

-  When using a track divided into 2 parts, assemble the track using the pre-installed joint on one of the two parts. To assemble the track, simply align the 2 

parts and slide the part without the joint into the part with the joint as indicated in fig. 5.

-  All Elvox tracks are supplied pre-tensioned. If it is necessary to tension the track belt, turn the tensioning bolt to adjust the tension (fig. 6a). A correctly 

tensioned track must have the lowest point of the loop formed by the upper stretch of the belt coinciding with the half way point on the track (fig. 6b).

-  Make 2 holes in the half way point of the architrave as shown in fig. 7. Make sure to drill the holes at a height that allows the door to slide under the track. 

In any case the highest point of the door must not be less than 10 mm from the track (fig. 8).

-  Fix the track to the architrave without tightening the fixing screws as shown in fig. 9. The track must be left free to turn.

-  Fix the support plate to the track at around 60 cm from the operator as shown in fig. 10a. Bend the two spacer brackets for assembly away from the ceiling 

to the required height and fix the brackets to the plate (fig. 10b).The spacer brackets are used to install the mechanism at a maximum distance of 38 cm 

from the ceiling (fig. 8). When fixing directly to the ceiling, do not use the spacer brackets.

-  Lift the track are fix to the ceiling with plugs (fig. 11), making sure that the track is perfectly horizontal (fig. 11) and that the highest point of the door is never 

less than 10 mm from the track.

-  Release the operator by pulling the carriage cord (fig. 12) and move the carriage near to the closing position

-  Hook the drive rod to the upper edge of the door (fig. 13).

Important:

 make sure that with the door closed the curved drive plate is at an angle of 45° to the track (fig. 16). If necessary, the plate can be shorted using 

the holes in the bracket to reach the required length.

-  Open the operator cover (fig. 15), unscrew the two fixing screws (fig. 16) and slide out the operator locking plate (fig. 17). Fix the operator to the track and 

replace the locking plate. Screw back the two previously removed fixing screws.

-  Move the door into the completely open position and fix the mechanical stop (fig.19a) at approx. 10 mm from the drive carriage (fig. 18). 

-  Fix the stop definitively by drilling two holes Ø 3 mm through the track but not into the stop (fig. 19b) and screwing in two 3.5 mm self-threading screws 

(fig. 19c).

Important:

 Drilling through the could damage the track belt.

-  Install the EBS4 lock release as indicated in fig. 20. The lock will fit in the block only with the key in and the lock positioned as shown in fig. 20d (notch A 

facing downwards). The end of the release cable must be tied to the release cord on the track carriage (fig. 20e). Remember not to leave the cable in the 

rest position (fig. 20f).

NOTE:

 the external release must be installed if there are no other access routes into the garage apart from the sectional door.

6. Mechanical installation on up-and-over door:

KLYS series sectional door operators can also be used to drive up-and-over doors with protruding counterweights using the adapter boom ENX6.

Before installation check:

-  that the distance between the track anchorage and the up-and-over door is no greater than 100 mm (fig. 21)

-  that the distance between the highest point of the up-and-over door and the track is between 10 and 20 mm (fig. 21)

3. Limitations of use:

Description

ENM1

ENM2

Power supply

115÷230 Vac - 50/60 Hz

Maximum absorption

1 A

1.5 A

Absorption in stand-by

1÷3 W

Electric motor power supply

24 Vdc

Electric motor maximum power

200 W

300 W

Max. drive/thrust

700 N

1000 N

Max. door surface area

9 m

2

12 m

2

Opening/closing speed

7÷12 m/min

Protection rating

IP10

Operating temperature

From -20 to +50°C

Dimensions

See fig. 2

Weight

1.6 kg

1.9 kg

Use

Residential

Apartment block

Frequency of use

50%

100%

Max. travel

2700 - 3700 mm

2. Technical data

Summary of Contents for ELVOX KLYS ENM1

Page 1: ...Manuale per il collegamento e l uso Connection and operating manual ENM1 ENM2 Attuatori 24 Vdc per porte da garage sezionali 24 Vdc actuators for sectional garage doors KLYS...

Page 2: ...Attuatore sezionale B Binario C Staffe per montaggio distanziato dal soffitto D Coppia di fotocellule E Lampeggiante F Radiocomando 2 canali G Selettore a chiave a b c 2x0 5 mm2 G I EN Key A Sectiona...

Page 3: ...3 KLYS 110mm 10mm max 38cm 60cm 7 5 6 8 9 10 a b a b Motor I EN...

Page 4: ...4 KLYS 45 11 12 14 13 15 16 I EN...

Page 5: ...5 KLYS 18 17 1 cm 19 a b c 20 mm 5 mm max 50 mm d f e A 20 a b c a b c d e f d f e A I EN a b c 3 mm...

Page 6: ...6 KLYS 100 mm max 10 20 mm 8 m S 20 30 mm 8 mm 21 22 a b 23 a b I EN...

Page 7: ...7 KLYS 24 25 N L 1 11 2 3 4 13 5 12 8 9 6 10 7 14 51 62 61 0 1 10 5 26 27 115 230 V ac I EN...

Page 8: ...8 KLYS RX1 C NC NA RX2 C NC NA TX1 TX2 RX1 C NC NA TX1 51 62 61 0 1 10 51 62 61 0 1 10 PHOTO COM 24V 51 62 61 0 1 10 PHOTO COM 24V PHOTO 24V 24V STOP P P 28 29 30 I EN...

Page 9: ...com pro met te re la si cu rez za del l ap pa rec chio L installatore deve as si cu rar si che le in for ma zio ni per l uten te siano pre sen ti sugli ap pa rec chi derivati Tutti gli apparecchi cos...

Page 10: ...rarsi che il binario sia perfettamente orizzontale fig 11 e che il punto pi alto della porta non si trovi mai a meno di 10 mm dal binario Sbloccare l attuatore tirando il cordino del carrello fig 12 e...

Page 11: ...ellule in chiusura vedere fig 29a e fig 29b I Installazione braccio adattatore tagliare la piastra di traino curva fig 22a in maniera che risulti solo rettilinea allargare a 8 mm il secondo foro della...

Page 12: ...ocellula morsetto 62 attivo in chiusura e in apertura Se il contatto aperto in fase di chiusura comanda la completa apertura dell automazione Se il contatto aperto in fase di apertura comanda un disim...

Page 13: ...la ricevente Segnalazioni della luce di cortesia e del lampeggiante durante la programmazione della ricevente 15 Luce di cortesia La luce di cortesia a bordo si accende ad ogni manovra dell attuatore...

Page 14: ...3 in ON Durante la taratura il motore parte e si ferma dopo 1 secondo Encoder non presente Controllare il connettore dell encoder motore sia inserito correttamente Forza motore bassa Aumentare la forz...

Page 15: ...61000 6 3 2007 A1 2011 EN 61000 6 2 2005 Direttiva R TTE 1999 5 CE EN 301 489 3 2002 EN 300 220 3 2000 Dichiara inoltre che la messa in servizio del prodotto non deve avvenire prima che la macchina f...

Page 16: ...nly be used for the purposes designed WARNING to prevent injury this apparatus must be securely attached to the wall in accordance with the installation instructions This leaflet must always be enclos...

Page 17: ...with plugs fig 11 making sure that the track is perfectly horizontal fig 11 and that the highest point of the door is never less than 10 mm from the track Release the operator by pulling the carriage...

Page 18: ...connect 1 or 2 pairs of photocells in closing see fig 29a and fig 29b Installation of adapter boom cut the curved drive plate fig 22a so that it is only straight 8 mm to enlarge the second hole of th...

Page 19: ...minal 62 active on closing and opening If the contact is open during closing controls the complete opening of the automation If the contact is open during opening controls disengagement stop and short...

Page 20: ...eiver from Rolling Code to fixed code and vice versa first delete all the receiver memory Courtesy and flashing light signalling when programming the receiver 15 Courtesy light The on board courtesy l...

Page 21: ...ON During calibration the motor starts and stops after 1 second Encoder not present Check the encoder motor connector is correctly plugged in Low motor power Increase the motor power with the POWER Tr...

Page 22: ...61000 6 2 2005 R TTE Directive 1999 5 EC EN 301 489 3 2002 EN 300 220 3 2000 Further hereby declares that the product must not be put into service until the final machinery into which it is to be inco...

Page 23: ...23 KLYS...

Page 24: ...Vimar SpA Viale Vicenza 14 36063 Marostica VI Italy Tel 39 0424 488 600 Fax Italia 0424 488 188 Fax Export 0424 488 709 www vimar com S6I ENM 100 06 16 01 VIMAR Marostica Italy...

Reviews: