14 - ENGLISH
7. ELIMINATION OF DEVICES
This procedure is used for eliminating devices from the system.
When carried out on a primary thermostat, the device will be
excluded from the network. When carried out on a secondary ther-
mostat, the device will lose the association with its actuator.
7.1 Eliminating a radio relay actuator
1. . Place the primary thermostat near the relay radio actuator.
2. Select
from the “installation menu” on the primary
thermostat (see paragraph 4.2).
3. Confirm. The display signals waiting with a rotation of the
symbol cursors.
4. Press the programming button on the radio relay actuator that is
to be eliminated.
5. If the actuator has been successfully eliminated, the
mes-
sage appears for a few seconds, alongside the network address
of the eliminated device.
Note.
After elimination of the relay actuator, the corresponding channels
will revert to the inactive state.
7.2 Eliminating the Internal Communication Interface
1. Place the primary thermostat close the Internal Communication
Interface.
2. On the GSM Communicator, configure the Internal
Communication Interface using the "Enrol Additional Devices"
procedure described in the separate Instruction Manual.
3. Select
from the “installation menu” on the primary
thermostat.
4. Confirm. The display signals waiting with a rotation of the
symbol cursors.
5. If the Internal Communication Interface has been successfully
eliminated, the message will appear for a few seconds, along-
side the network address of the eliminated device.