Input wiring.
The control unit is supplied with non-jumpered normally closed safety inputs (STOP, SCL, SOP).
Add a jumper between the common (COM) and the input you do not intend to use. LEDs DL2 DL4 and DL5 must be on.
A
ccessories -24VDC
A
cces24VDC
Light 2W max +24VDC
C
ommon (negative)
C
ommon (negative)
Sequential/Start N.O.
Stop N.C.
Pedestrian N.O.
Safety device when closing N.C.
Safety device when opening and closing N.C.
Electrical lock +12V
AC 15V
A
Electrical lock -12V
AC 15V
A
O
pens N.O.
Safety T
est/2nd radio chan.pulse + 24VDC
Connecting control push buttons and keyswitch.
The contacts are normally open. Input SEQ (LED DL1) controls the opening or complete closing of the gate. Input PED (LED DL3) controls the opening
or partial closing of the gate. LEDs DL1 or DL3 and LED DL7 light up when the keyswitch or push buttons connected in parallel are operated.
Control push button
PED
Control push button
SEQ
N.C.
N.C. N.O.
N.O.
24
SW230.T / SW230.T.120
EN