44
4
5
6
7
8
3
7602050
3
Top limit switch -
Right hand
Bottom limit switch -
Left hand.
Limit switches activated.
Telephone fault finding action:
Ask client to tap trunnion guards in case they are stuck. If
this does not correct the fault – send engineer.
Displayed troubleshooting on site:
Check the limit switch circuit and the joint pin protection.
4
Top Right cover
pressure;
Bottom Left cover
pressure
- Footboard
Safety edge (up/down direction) activated - footplate.
Telephone fault finding action:
Ask the customer to tap the footplate edges. If this does
not correct the fault – refer to engineer.
Displayed troubleshooting on site:
Check the footplate main profiles.
5
Bottom limit switch -
Right hand
Top limit switch - Left
hand.
Limit switches activated.
Telephone fault finding action:
Ask client to tap trunnion guards in case they are stuck. If
this does not correct the fault – send engineer.
Displayed troubleshooting on site:
Check the limit switch circuit and the joint pin protection.
6
Bottom pressure -
Right hand
Top pressure - Left
hand.
Footplate safety edges and cover (up/down direction)
activated.
Telephone fault finding action:
Ask client to tap footplate edges. If this does not correct
the fault – send engineer.
Displayed troubleshooting on site:
Check footplate bottom and downside and power pack
cover.
7
Low voltage.
Batteries approaching critical level.
Telephone fault finding action:
Ask client to drive lift to charge contacts - if ‘Okay’ code
does not show send engineer. If the lift will not drive - send
engineer.
Displayed troubleshooting on site:
Drive lift to charge contacts. Check charging circuit if ‘Okay’
code not displayed. If lift will not drive replace batteries and
check charging circuit.
8
Up direction -
Right hand
Down direction -
Left hand.
Shows when toggle switch is activated in up/down direc-
tion.
Telephone fault finding action:
None.
Displayed troubleshooting on site:
None.