45
E
A
C
7602050
9
Up direction -
Left hand
Down direction -
Right hand.
Shows when toggle switch is activated in down/up direc-
tion.
Telephone fault finding action:
None.
Displayed troubleshooting on site:
None.
B
Switch active.
A switch is active at power on i.e. Toggle Up, Toggle down,
IR Up IR down or learn.
Telephone fault finding action:
Send engineer.
Displayed troubleshooting on site:
A short circuit has occurred on toggle circuit - check cir-
cuit.
D
Relay not open
(stopped).
The main power relay is welded closed.
Telephone fault finding action:
Send engineer.
Displayed troubleshooting on site:
Replace main board.
E
Relay not closed
The Main Power relay did not close.
Telephone fault finding action:
Send engineer.
Displayed troubleshooting on site:
Replace main board.
A
Hinge open.
Telephone fault finding action:
NOT YET ACTIVE.
Displayed troubleshooting on site:
NOT YET ACTIVE.
g
Brake not
connected.
Telephone fault finding action:
Send engineer.
Displayed troubleshooting on site:
Check brake.
C
IR Address fail.
The IR Address (Dip switch) does not match.
Telephone fault finding action:
Send engineer.
Displayed troubleshooting on site:
Re-program handsets.
n
Half speed.
Telephone fault finding action:
Send engineer if permanently showing.
Displayed troubleshooting on site:
Check reed switches and dipswitch
settings.