About this document
This document is intended for users of all version 6.0 VSP-M
station models (VSP-211M-L, VSP-212M-L, VSP-213M-L,
and VSP-22M). The system can handle up to 20 stations.
Extension Number Configuration
Each VSP-M station must have its own unique extension
number, 00 to 19, set by DIP switches. The DIP switches are
activated by sliding them to the ON position.
To set the extension number:
1. Remove jumpers from pins J2 and J3.
2. Set the first digit (
Group
) in the extension number
according to: switch 11 = 0 or switch 12 = 1
3. Set the second digit in the extension number according
to: switch 1 to 10 where switch 1 = 0, switch 2 = 1 ....
switch 10 = 9
Example:
–
For extension no. 03, set switch 11 and 4 to ON.
–
For extension no. 11, set switch 12 and 2 to ON.
F
igure 1: DIP switches for setting VSP-M extension number 11
For information on all extension number settings, see
section
7: DIP Switch Settings for Extension Numbers
in
A100K10758
VSP-M Technical Manual
.
Extension Number Label
A label strip with numbers 00 to 19 is shipped with each
station.
●
Fix the label with the relevant extension number in the
frame next to the text
Station no
at the front of the
station.