TECHNICAL MANUAL

ACM Family 

System Installation & Configuration

A100K10647

Summary of Contents for AACM-144-V10

Page 1: ...TECHNICAL MANUAL ACM Family System Installation Configuration A100K10647 ...

Page 2: ...V10 AACM 144 V10 17 4 3 Installing Feature Boards 17 4 3 1 Hot plug 17 4 3 2 AMC IP AlphaCom Module Controller Board 17 4 3 3 Board positions 18 4 4 Connection Terminals 18 4 4 1 ACM M A V2 and ACM M D 18 4 4 2 ACM 48 V10 20 4 4 3 ACM 144 V10 and AACM 144 V10 20 4 4 4 ACM M D IP72 ACM M D IP96 21 4 5 Power Supply 21 4 5 1 ACM M A V2 ACM M D 21 4 5 2 ACM 48 V10 ACM 144 V10 AACM 144 V10 21 4 5 3 ACM...

Page 3: ...erview 44 Configure au io inter a e rom S A to ACM 45 Configure ACM A ones 47 Configure au io inter a e ACM to S A 48 7 7 5 Feedback Intercom as PA panel 50 7 7 6 Delayed PA Message Recall 50 8 ACM System Racks Specifications 51 8 1 ACM M A V2 51 8 2 ACM M D 51 8 3 ACM 48 V10 52 8 4 ACM 144 V10 52 8 5 AACM 144 V10 53 8 6 ACM M D IP72 ACM M D IP96 53 8 7 Environmental Requirements 54 9 Appendix A E...

Page 4: ...5 Figure 22 Audio input connection 28 Figure 23 Connect PC to Eth0 34 Figure 24 Cold start 37 Figure 25 Cold start to load default database 37 Figure 26 Cold start and keep IP settings 37 Figure 27 Integrated PA GA Overview 44 Figure am le onfiguration o ay ommuni ation 55 Figure am le onfiguration u li A ress on on entional essels 56 Figure am le onfiguration o Integrate A A oo A 57 Figure am le ...

Page 5: ...69 SPA V2 PA GA System Manual A100K10370 SPA V2 PA GA Configuration Installation Manual A100K10371 SPA V2 PA GA User Manual A100K10805 AlphaCom XE Installation Configuration Operation A100K10390 SIP GSM Gateway MV 370 A100K10333 SIP Analog Gateway AudioCodes MP 114 MP 118 A100K10590 Billing System Configuration Guide A100K10610 LCM Line Connection Module A100K10652 IP DECT Installation Configurati...

Page 6: ...ddress part of the system comes through it a su erior soun uality In a ition t e system su orts a i e range of supplementary services such as External telephone interface Billing of external calls General PBX functions DECT cordless telephones Data networking and cable distribution Paging Music entertainment Integration with iPBX e I ACM system su orts a i e range o on entional I SI an ireless ter...

Page 7: ... ition an ACM installation may onsist o su lementary systems SPA V2 Public Address system Data network system 2 2 1 ACM main system rack The ACM main system rack is the central unit in the whole system It onne ts all fiel e ui ment an ro i es all main entral ser i es Several system racks can be connected via the data network The VINGTOR ACM family includes the following main system racks ACM M A V...

Page 8: ... three i erent si es is is t e Al aCom Al aCom an AlphaCom XE26 These intercom exchanges use Same line and interface board ASLT for PA and intercom units 6 lines and one conversation channel per board Same telephone line interface board ATLB 12 for analog telephones 12 telephone lines per board Same processor board AMC IP Same software and functions AMC software Same set of conventional intercom s...

Page 9: ...lowing capabilities Two way communication Signal units The signal units are used in noisy areas to provide visual indication of alls an lou er ringing u er signals Loudspeakers The loudspeakers are connected to intercom stations or intercom line points 2 2 3 Supplementary systems VINGTOR SPA V2 Public Address system The SPA V2 Public Address system is integrated into the overall solution to provid...

Page 10: ...N x x x x Chief Eng Cabin N x x x x x Bedrooms N x x x Cabin bathrooms x Office N x x x x x Mess room N x x x x Galley N x x x x Conference room N x x Corridors x x Staircase x x Gym N x x Wardrobe N x x Hospital N x x x x Electrical workshop N x x x x Dayrooms N x x x x x Elevator N x x Fire Station N x x Instrument room N x x x x x Switchboard rooms N x x x x x DP Control Center N x x x x x Engi...

Page 11: ...om XE intercom module within the ACM racks The following marine regulatory requirements are supported Special purpose stations Priority Communication to noisy areas Volume control Capacity Special purpose stations The ACM system supports a set of special purpose stations for different s i en ironments in lu ing Bridge and Console stations Watertight stations Stations must have a rating of IP56 for...

Page 12: ...tion to ar s t e noisy area t e remote user can use the push to talk key when talking Using this key will also increase the volume at the remote end Volume control It is ossi le to onfigure t e soun ressure le el or ea ACM station according to requirements for the location where the station is placed The user can also tune the audio level on most stations Some call types include a volume override ...

Page 13: ... adjusted via the AlphaPro programming tool Some of the ACM intercom stations have local volume control to adapt olume to t e esire le el o e er uring a A announ ement t e ACM intercom exchange will carry out a volume override of the volume level as set in AlphaPro PA and GA broadcast in noisy areas e ACM system as relay out uts t at ill ri e as ing lig ts in noisy areas during a PA and GA announc...

Page 14: ...ACM system together with SPA V2 Redundant racks passenger vessels assenger essels re uire t o A ra s ea lo ate in a i erent fire one e figure s o s o t e ra s are u li ate y using an ACM system toget er it one S A ra in one fire one an a second SPA V2 rack in another Figure 4 Basic PA GA for passenger vessels 1 4 7 M 2 5 8 0 3 6 9 C VINGTOR VMP 503 ON CALL A A B B GENERAL ABANDON MANUAL RESET EMS ...

Page 15: ...VMP 530 and VMP 503 stations are used in the other talk back positions These stations can be extended with an external speaker for louder volume and or headset For ot M an M you nee to ress t e us to tal key to become an active speaker in the conference When the VMP station is t e a ti e tal er in t e on eren e t is ill e in i ate y t e green LED for the DECT handset DECT handsets The ACM system s...

Page 16: ...ble inlet is at the bottom of the system rack Make sure there is enough space around the rack for connection and servicing Figure 6 Clearance Dimensions for ACM M A ACM M D cabinets 4 2 2 ACM 48 V10 e ACM system ra is ma e or all or oor mounting Mount t e a inet at a on enient eig t it t e ottom a out m a o e t e oor Cable inlet is at the bottom of the system rack Make sure there is enough space a...

Page 17: ... 3 2 AMC IP AlphaCom Module Controller Board All AlphaCom servers in the XE series have one AMC IP board delivered at shipment This AMC IP board is the next generation multi service board developed for the STENTOFON AlphaCom XE series The board is made for critical communication and security solutions featuring an embedded real time inu o erating system integrate me ia ro essing engine a et ro ess...

Page 18: ...ks See Section 5 for example 4 4 1 ACM M A V2 and ACM M D Connectors and terminals for power and external equipment are accessible at the rear of the ACM M A V2 and ACM M D cabinet o a ess t e onne tors o en t e a inet oor an s ing out t e AlphaCom XE7 exchange Cable inlets are at the bottom of the cabinet and there is a cable fastening bar in the lower part All internal cabling is ready made from...

Page 19: ...om lines PA Phone analog lines for MP114 Power supply RCI Figure 12 Terminals in ACM M A V2 Figure 13 Terminals in ACM M D 230 VAC UPS 230 VAC mains Relay mains 24 VDC input AC fail relay 24 VDC in out DC fail relay Ground bar X3 X2 X1 X4 X5 X6 X7 Intercom lines PA Phone analog lines for MP114 Power supply RCI 1 1 1 1 1 1 1 1 Diode Rectifier Ethernet Switch Injector PoE Switch Power supply ...

Page 20: ...rs o en t e a inet door and swing out the AlphaCom exchange frame Cable inlets are at the bottom of the cabinet and there is a cable fastening bar in the lower part All internal cabling is ready made from the factory and routed in cable conducts ACM as CM terminal mo ules while AACM 144 has 4 The number of terminals and physical la ement o terminals or o er et may ary according to optional equipme...

Page 21: ... circuit breaker if this backup power is used The 230 VAC mains outlet X7 is used for service purposes Figure 16 ACM M A D Power connection Power failure Three power fail relays are included to indicate the types of failures Each relay has a NO NC switch over contact to indicate Power good fail The relays are a ti ate en t e a tual o er is i means t at t e NO contact is closed and NC is open under...

Page 22: ...o er ails t e AC S or o tional C ill e connected A set of NO NC contacts are available at X4 terminal for indication and warning Figure 17 ACM M D IP72 ACM M D IP96 Power connection 4 5 4 Cable dimensions All mains and UPS cables should be 1 5 mm2 I C s oul e use as emergen y o er t e o er sour e capacity as well as the cable length and cross section must be evaluated Keep in mind that the minimum...

Page 23: ...r Input Output 3 x 1 A fused outputs relay ontrolle s it sele te C out uts A ommon use Line points Max 36 x analog intercom stations on 6 x ASLT boards or Max 60 x analog telephone lines on 5 x ATLB12 boards max 5 x 4 wire intercom stations on 1 x ASLT board 1 x intercom station as PA monitor RCO 1 x relay contact for PA control relay onta ts otential ree or s it sele tion RCI Needs APC board not ...

Page 24: ...m2 twisted pairs and an outer braided tinned copper screen The screen must be interconnected in junction boxes and grounded to a common ground point in the ACM system rack only Figure 19 Telephone and intercom line connection example 4 6 3 RCO Remote Control Outputs There are outputs from 6 RCO relays which can be programmed to operate external features like extra signal devices in noisy areas All...

Page 25: ...ila le on A an The feature programming is performed in AlphaPro Figure 21 RCI closing contact connection ACM M A V2 The AlphaCom XE7 in ACM M A V2 has no option for an APC card There are two RCI inputs on the AlphaCom XE7 backplane RCI1 RCI2 4 6 5 PA Connection The description below refers to the SPA V2 Public Address system See t e S A manual A or urt er etails t er am lifiers may e onne te in a ...

Page 26: ... e ON Set switch S18 to ON to a ti ate t e au io filter Set switch S9 to ON to simulate audio out load when monitor station is missing Set switch S10 to ON to simulate audio in load when monitor station is missing ea e s it es S S an S OFF Set olume ontrol OUT2 to mi osition This must be readjusted to 1 0 5 Vrms during live test Set switch S1 in Potent Free position for chime activation Intercom s...

Page 27: ...dio on the LCM unit and the radio input terminal Connect the cable screen to system ground Conne t a s reene t iste air a le et een in on terminal in on terminal OUT1 Audio on the LCM unit and the radio input terminal Connect the cable screen to system ground Connect cables between terminals 6K 6K on the LCM unit and the PTT terminal on the radio Set switch S7 to ON to a ti ate t e au io in ut fil...

Page 28: ...ule Set all 8 jumpers S11 16 S19 20 to the APC position Connect the audio source cables to spring lock terminals P0 to P5 34C 36D Use 2 wire screened cables to connect the screen to system ground Figure 22 Audio input connection Each audio source volume level is individually adjusted on the APC board The feature programming is done in AlphaPro 4 7 ACM IP Patch Panel I Os The ACM IP system comes wi...

Page 29: ...107 277 1 2 3 Chief Eng Day HSB03 1 4 4 Parallel ringing 2 1 108 278 1 2 3 Chief Eng Bed DT 800M 1 4 4 Parallel ringing 2 1 109 279 1 0 1 Mess room TC1020 1 5 5 Member ringing group 6701 1 110 280 1 0 1 Hospital DT 800M 1 5 5 1 111 281 1 0 1 Station 11 1 6 6 1 112 282 1 0 1 Station 12 1 6 6 1 113 7 1 0 1 Station 13 1 7 7 7 7 Intercom station 2 114 8 1 0 1 PA monitor VMP 619 1 8 8 8 8 PA monitor st...

Page 30: ...grou use or emergen y A announ ement is programmed as group 1 with group access level high Only users with group access level high can make an emergency PA announcement Class of Service COS COS determines which system features the station can activate There are 16 different classes available and each can be freely rogramme A station analog tele one an only a e one efine COS An ACM solution is usua...

Page 31: ...ace y e ault t e system is rogramme to su ort emergen y A announcements ALL CALL initiated from analog telephones with group access level 2 INTEGRATED PA INTERFACE Signal direction Type LCM A B C D RCO Terminal Info ACM to SPA Audio 0dB 1 8 8 CM Au io 8A B for PA monitor ACM to SPA PA ALL CALL RCO1 CM S1 Pot free Table 7 Integrated PA interface example A A CA is a esse y ire tory no e all is onfig...

Page 32: ...asic 1 2 002 FXO MP 114 2 2 6701 Trunk 2 Basic 3 4 003 FXO MP 114 2 3 101 Trunk 3 Extra 5 6 004 FXO MP 114 2 4 101 Trunk 4 Extra 7 8 Table 9 Trunk lines example Directory No The number to dial to get an external trunk line SIP type The SIP gateway used for the trunk Possible types are MP 114 and MP 118 FXO is the supported analog telephone interface from the MP gateways Node The AlphaNet node numb...

Page 33: ...nsferred AlphaPro can also upload onfiguration in ormation rom an e ange Al a ro onne ts to t e AlphaCom XE over an IP network AlphaWeb AlphaWeb is an embedded web server running on the AlphaCom XE server exchange It allows the users to log in using a standard web browser to operate and manage the AlphaCom system 6 1 AlphaWeb Getting Started AlphaWeb XE Interfaces Routers IP Station Upgrade Licens...

Page 34: ...p Click Login for Unsecure AlphaWeb http unless encrypted access to the Internet is required for safety reasons The user will be prompted for a user name and password The default login for a user with reading rights only is User name alpha Password com o e a le to ange t e onfiguration t e user must log in as an administrator The default login will then be User name admin Password alphaadmin A in ...

Page 35: ...its icon Each main menu will have one or more selectable tabs or submenus Al a ro may e run it out eing onne te to ACM o line an all changes can be saved to the PC and copied to the system later on It is good practice to start the programming in the Exchange System menu and continue rightwards on the menu bar 6 2 4 Creating a New Network and Exchange en onfiguring t e settings or an e ange or t e ...

Page 36: ...e ACM exchange Establish data communication Click the Connection icon The Communication window appears e onne tion is onfirme en t e ommuni ation is established and the buttons will then become active Send information to the exchange en t e esire anges to t e rogramming are one t e ne onfiguration ata ase must e loa e into t e e ange Click SendAll to send all data Click on SendChg to send changed ...

Page 37: ...efault IP address to 169 254 1 5 with subnet mask 255 255 0 0 on Eth0 7 2 1 Cold start procedure Turn the exchange mains switch ON auto fuse at the rear of the cabinet Press and hold the cold start button on the AMC IP board ress t e reset utton lo ate on t e o er ar rie y Keep the cold start button pressed at least 5 seconds after reset The AMC status LED will blink green when the boot is ready 7...

Page 38: ...ntil all address routing and filter changes have been saved Set IP Routes Route type host is used to set up a route to a single device outside the subnet of ACM Route type net is used to set up a route to another network Route type default is used to set up a general route to any device outside the subnet of ACM Select System Configuration Routes Select the type of IP route by clicking Add Route D...

Page 39: ...hapter describes how to program the system user and station directory in order to comply with marine requirement for emergency two way communication The chapter is divided in the following parts General user settings Program different class of service for users Program call priority e ore you ill e a le to rogram t e user an station ire tory t e rogram an Ca le e eren e ist must a e een fille in S...

Page 40: ...criber s name The max number of characters is 16 including the station directory number Visibility This can be set to Local or Global Visibility is related to AlphaNet when cluster programming is used Local station can be addressed inside the node only Global station can be reached from all nodes in a cluster A luster is a su net o a net or an onsists o a num er o efine nodes Station Type se to ef...

Page 41: ...lls a user may make Each grou use or grou an A alls ill a e an asso iate Group Access Level The levels are Low Medium and High The user must have a higher or the same group access level y e ault t e grou use or emergen y A announ ements are programmed as Group 1 with group access level High Only users with group access level High can make an emergency PA announcement Call Setup Priority Used to sp...

Page 42: ... is usually programmed with the following Classes of Service COS 1 Regular stations in the system COS 2 Notify busy station C S erri e o usy a sent an ri ate COS 16 Includes all services Default for SuperUser Create a new Class of Service Click on the Class of Service icon The Class of Service window is opened Select the Class of Service you want to modify and click Change A window to change the s...

Page 43: ...ammed for handsfree two way communication Talk Back according to marine requirements Talk Back units The VMP430 or IP Master Flush Station is used as the main talk back anel on t e ri ge In ot er tal a ositions t e M an VMP530 intercom stations are used This section describes how to program the system for directory bridge station VMP 430 bridge station IP Master Flush Station other talk back units...

Page 44: ...V2 Public Address panels and ACM intercom panels based on customer requirements Loudspeaker solution ACM intercom stations used in two way voice communication can broadcast PA and GA announcement When a PA or GA message is laye in an inter om station t ese ill e one it olume o erri e in order to override any volume setting by the user Interface ACM to SPA V2 A normal subscriber user extension is u...

Page 45: ...I programming will trigger an event type 15 Event Trigger Feature in t e e ent an ler ere station ysi al no 400 is the event owner and directory number 5001 is the Related to number The actual commands to be executed are programmed in the event handler Click the Exchange System icon Click RCI Select Input 1 RCI 1 to be used to signal audio from SPA Click Change In the ON Action fiel enter ER U15 U...

Page 46: ...U0 MCC U2 U5 U0 MCC U3 U5 U0 MCC U4 U5 U0 MCC U5 U5 U0 MCC U16 U5 U0 PRG 10 5 CAC U10 Click OK Set the OFF event e rogramming ill first turn o t e au io rom in ut no to grou en t e rogram sele tion in lass o ser i e to grou 16 will be restored Click the Exchange System icon Click Events Click Insert Select Station Id from the Owner Type ro o n list an enter 400 in the Id fiel Select 15 Event Trigg...

Page 47: ...embers list Use the double right arrow button to transfer all stations in the list to the Members list se t e single le t arro utton to e lu e stations li e t e A initiating stations rom t e Members list Click OK to update records 7 7 3 Configure ACM PA zones The ACM system can assign the different ACM intercom stations into groups o onfigure multi le A ones t e ACM inter om stations t at are use ...

Page 48: ...A V2 Select RCO for Push to Talk A normal subscriber user extension is used as the interface from the ACM system to t e S A system At ea su s ri er osition t e ACM has a remote control output where RCO 1 is at subscriber position 1 and so on e C is use to signal an one sele tion to t e S A system Click the Users Stations icon Select the subscriber station used as the interface to the SPA system fr...

Page 49: ... on all telephones The owner is therefore UDP8 related to directory no 84 Group Call If any station starts up an outgoing on ersation ent ty e y sele ting t is e ent ill start This programming will activate three events in the system The loudspeaker in the station who has enabled the action will be isa le en t e an set is a ti e an automati ally ena le when the handset is not active Program distri...

Page 50: ...he PA panel and the other intercom stations Click the Users Stations icon Select the subscriber position used as PA panel from the list Click Group Excl Select the neighboring intercom stations from the drop down lists Click OK 7 7 6 Delayed PA Message Recall The ACM Recall eature ena les t e user to re or e an lay a live PA broadcast call y using elaye lay a au io ee a ro lems are a oi e as no mi...

Page 51: ...lnet FTP TFTP NTP HTTP HTTPS Syslog SNMP v2c SIP RTP RTCP VoIP AlphaNet STENTOFON data OPC Remote system management AlphaPro over IP Web 8 2 ACM M D Dimension mm 600W x 600H x 350D Weight 45 kg Mounting Wall mounted Temperature range 0 55 C recommended 18 25 C Power 230 VAC mains max power 260 W 24 VDC emergency max power 260 W Automatic switch over between mains and emergency IP class IP 20 Subsc...

Page 52: ...P TFTP NTP HTTP HTTPS Syslog SNMP v2c SIP RTP RTCP VoIP AlphaNet STENTOFON data OPC Remote system management AlphaPro over IP Web 8 4 ACM 144 V10 Dimension mm 800W x 1250H x 600D Weight 180 Kg Mounting Floor mounted Temperature range 0 55 C recommended 18 25 C Power 230 VAC mains with auto switch over to 230 VAC emergency Option 230 VAC mains with auto switch over to 24 VDC emergency IP class IP 2...

Page 53: ... D IP96 600 x 1350 x 600 mm Weight ACM M D IP72 Approx 107kg without switches or accessories ACM M D IP96 Approx 117kg without switches or accessories Material Powder coated steel RAL7035 Mounting Floor mounted IP class IP 22 Temperature range 0 55 C recommended 18 25 C Power supply 230V AC Mains with switchover to 230V AC UPS 115V AC optional Power consumption Without switches and no accessories ...

Page 54: ...nts a or ing to EN 60945 and IACS E10 standards Rack Temperature 0 C to 55 C Humidity 95 RH 25 C 93 RH 55 C Compass safety Distance to ACM rack 325 cm Distance to telephones 95 cm L It is strongly recommend to install the rack in a ventilated technical instrument room with temperatures between 18 C and 25 C This will extend system lifespan ...

Page 55: ...55 ACM Family System Installation Configuration A100K10647 9 Appendix A Example Configuration Diagrams 9 1 Two Way Communication Figure 28 Example configuration Two Way communication ...

Page 56: ...56 A100K10647 ACM Family System Installation Configuration 9 2 Public Address on Conventional Vessels Figure 29 Example configuration Public Address on conventional vessels ...

Page 57: ...57 ACM Family System Installation Configuration A100K10647 9 3 Integrated Public Address and General Alarm Figure 30 Example configuration of Integrated PA GA Loop A ...

Page 58: ...58 A100K10647 ACM Family System Installation Configuration Figure 31 Example configuration of Integrated PA GA Loop B ...

Page 59: ...ndset SAFE 10PT Loudspeaker 100V 10W Bathrooms SPA V2 Am lifier ra 230 VAC Mains 24 VDC Emergency 2 x SPA 120 240 400 2 x EE3 signal generator Mute contacts CAR 4T or CAR 6T Loudspeaker 100V 4 or 6W Corridors SPA AC6D Alarm anel ual system A an on general or manual alarms Alarm reset button Emergency button EMS for PA message ACM RJ45W 7 Junction box for IP Desk Master Station SPA M6S A anel singl...

Page 60: ... PCB 2030010260 AlphaCom Mains Transformer 6A 230 VAC to 24 VAC transformer for XE7 1009701000 AlphaCom AC power supply Power supply for XE20 and XE26 exchanges 1009202100 AlphaCom AMC IP processor board Main processor board intercom exchange 1009301000 AlphaCom APC board Audio input card for XE20 and XE26 exchanges 1009101010 AlphaCom ASLT2 board Conventional intercom line board 1009104000 AlphaC...

Page 61: ...m desktop IP intercom Order no Description Function 1008031000 I us master is lay IP intercom console 1008097100 an set or I us master Handset 1008097500 Gooseneck microphone oosene mi ro one or I us 1008010100 IP CRM V DAK module ey omman mo ule or I us 1008001000 I es to master is lay an an set IP intercom desktop Analog telephones Order no Description Function 2213000300 AF Flus onsole mount an...

Page 62: ...V DC Signal for intercom unit A 100 Alarm orn C Signal for intercom unit A 100AC Alarm orn AC Signal for intercom unit HB 105 ele one one Caller For analog telephone HB 90 ele one one Caller For analog telephone SON 16 Com ine lam u er C Signal for intercom unit AL 1000 Com ine lam u er AC Signal for intercom unit AL 105N WR 0 Com ine lam orn C Signal for intercom unit CRB 7 elay o atertig t Relay...

Page 63: ...A100K10647 11 Appendix C Internal Power Wiring in System Racks 11 1 ACM M A V2 11 2 ACM M D V2 X 230V 0 3A max 50 60 Hz 230V 0 3A max 50 60 Hz X X 0 5 mm2 0 5 mm2 0 5 mm2 0 5 mm2 0 5 mm2 0 5 mm2 0 5 mm2 0 5 mm2 0 5 mm2 2 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2 ...

Page 64: ...64 A100K10647 ACM Family System Installation Configuration 11 3 ACM 48 V10 11 4 ACM 144 V10 al Ethernet al ...

Page 65: ...65 ACM Family System Installation Configuration A100K10647 11 5 ACM M D IP72 11 6 ACM M D IP96 ...

Page 66: ...lls to a ringing group consisting of multiple crew stations All re anels ill ring allo ing t e all to e a e te at any re panel Call Request Mode is the default mode for Talk Back members calling to the Bridge Talk Back members are informed with a message that their call is in a ueue an t e ri ge is notifie it a u er as ing utton an call queue in the display Group Call Mode is the default method fo...

Page 67: ...ssaging license offers a broad set of applications and un tions some o i are Live PA and group call broadcast with recall for handling feedback and verifying messages Pre stored PA and group call broadcast Scheduled or event based PA and group call broadcast Auto Attendant with voice guided menus for handling incoming calls Voice response for call request waiting messages and absence messages Inte...

Page 68: ...ing t e e inter a e Al a e e stan ar messages om rise Absence messages Information messages Help messages Alarm messages The types of messages that actually become available depend on the installed Audio Messaging license Install language package e language file as t e ormat asvp_xx_06 00 apkg ere xx is the actual language and 06 00 is the version number e ore t e installation an start you nee to ...

Page 69: ...s are recorded from a station e au io file an e re or e on a C or in a ro essional stu io i ig uality lay a is re uire e au io file must e in A ormat The following codecs are supported CM files at sam le rate linear it mono annel MS A CM at sam le rate mono annel IMA A CM at sam le rate mono annel en a re uest is ma e to Al aCom to lay a message it ill search for matching group index in the follow...

Page 70: ...icense required 8191 Alarm Message 1 30 1 Fire alarm Please stay calm and leave the building through the nearest exit All exits are marked with green light Don t stop but proceed completely out of the building Wait for further information outside Basic 8192 Alarm Message 2 30 2 The situation is now under control the building can again be used We are sorry for the inconvenience Basic 8193 Alarm Mes...

Page 71: ... accessed from the System Configuration Messaging page in AlphaWeb e A file ill e store it t e file name svp_ggg_iiia_ wav where ggg is t e Message rou num er iii is the Group Index number and a indicates that it is a station recorded message and not a web loaded message You are only allowed to record messages according to the type of Audio Messaging license installed o e a le to arry out station ...

Page 72: ...iles at sam le rate linear it mono annel MS A CM at sam le rate mono annel IMA A CM at sam le rate mono annel CM files nee yte s e A CMs nee yte s same as G 711 G 722 Station recorded Easy Messages are stored as IMA ADPCM 13 3 Recall The Recall function lets you record a message from a station and then dispatch the recorded message as a Group Call The function is used to prevent feedback problems ...

Page 73: ...ry number y e ault t is arameter as alue RECALL OPTIONS Value parameter 2 Function 1 After playback to the group has finished the group call and the initiator station will proceed to normal Group Call mode and can use the M key to talk into the group 2 If the initiator station disconnects during playback to the group the message is terminated immediately 8 The initiator station will not listen to ...

Page 74: ...taneous Group Calls A group call is canceled by a group call with higher priority if there is overlap between members Without Simultaneous Group Calls An ongoing group call is canceled by a group call with higher priority 13 3 5 Hardware and software requirements Hardware The recall function can be used on AMC IP board versions 10 red PCB and 11 black PCB Software Recall is available from AMC IP s...

Page 75: ...Adding a second Auto Attendant In Directory Features li Insert and add a new number with the following properties Dir no Display Text Feature Parameter 1 User no Parameter 2 Parameter 3 Description 9551 AutoAttendant2 105 0 2 501 Auto Attendant number 2 using Stored Voice Message 2 and the DAK table of physical number 501 o re or a message ial 8180 9551 M key Digit routing is done in the DAK table...

Page 76: ... Assurance System is certified to meet the requirements in NS EN ISO 9001 Zenitel reserves the right to modify designs and alter specifications without notice ZENITEL PROPRIETARY This document and its supplementing elements contain Zenitel or third party information which is proprietary and confidential Any disclosure copying distribution or use is prohibited if not otherwise explicitly agreed in ...