G.3. AIR-CONDITIONNING UNIT
-
Turn on the air conditioning (switch at end of strip).
-
The green light should come on.
-
The internal fan operates continuously.
-
The external fan operates only when the unit is cooling.
-
The unit thermostat is preset to maintain a constant
temperature of about 12 to 13°C inside the wine cellar.
-
This temperature can be adjusted between 8°C and 15°C
by turning the control knob.
-
If the temperature outside the cellar drops too low, (in
winter, for example) and there is a risk that the
temperature inside the cellar will fall, a heater within the
air conditioning unit will automatically take over from the
refrigeration system in order to maintain the ideal
temperature
SETTING AND ADJUSTING THE TEMPERATURES
The set values in the thermostats are not temperatures in grades, but indexes. A 1 unit index value is
close to 1° Celsius. It is necessary to wait 48 hours to check the impact of a temperature adjustment on
the thermostat.
Electronic regulator
(Picture D1)
:
B1 :
Displays the requested value
Validates the set value
B2 :
Increases the requested value
B3 :
Decreases the requested value
L1 :
Flashes during a programming phase
L2 :
The heating resistance is active
L3 :
The compressor is active
Pict.D1
Display and programming of the desired index value:
-
Press
B1
until you read the message
Set
.
-
Press
B1
a second time to display the wished index value.
-
Change this value using
B2
&
B3
.
-
Save this value by Pressing once more on
B1
.
-
To confirm the value is saved, the message
Set
will be displayed.
After some time the display gets back to normal mode (display of the actual internal temperature).