J. MAINTENANCE
TEMPERATURE TOO LOW
The thermometer is not showing the correct reading
: Check by using another thermometer.
Thermostat set too low
: Raise the temperature gradually to avoid subjecting your wine to sudden
changes in temperature.
TEMPERATURE TOO HIGH
The thermometer is not showing the correct reading
: Check by using another thermometer.
Thermostat set too high
: Lower the temperature gradually to avoid subjecting your wine to sudden
changes in temperature.
Door not properly closed
: Check that the door closes and locks correctly.
Ventilation in the room where the wine cellar is installed is inadequate (this problem usually
arises when the outside temperature is high)
: If possible, open the door or windows. Install a
ventilation system in the room (ventilation grill, extractor fan, etc…)
Thermostat setting decreased too suddenly
: Causes the air conditioning unit to ice up.
Air conditioning unit iced up
: Turn the air conditioning unit off for 48 hours and turn on again,
ensuring that the thermostat is set on 13 °C or 14 °C. If the problem persists, disconnect the main
supply, remove the air conditioning unit from the wall (page 10) and clean the condenser using a vacuum
cleaner. This maintenance is not covered by the guarantee.