TROUBLESHOOTING 

 

If your cooler does not work properly, please note the following suggestions 
before you attempt to repair or replace the unit. 
 
Your cooler does not work: 

 

Check the electrical outlet for power and that the plug is properly plugged 
in. 

 

Check the condenser for proper cleaning. 

 

The circuit breaker is tripped or the fuse is blown. 

 
Your cooler makes too much noise: 

 

Check that the cooler is level. 

 
Compressor turns on and off frequently: 

 

The room temperature is higher than normal. 

 

The door is not closed completely. 

 

The door gasket is not sealed well. 

 

There is insufficient clearance around the cooler. 

 

The cycling frequency will reduce when all of the cans reach the set 
temperature. 

 
The following is not a malfunction: 

 

It is normal to hear gurgling sounds caused by the flow of refrigerant 
when each cooling cycle ends. 

 

CIRCUIT DIAGRAM 

 

sensor

Computerized

Controller

Overload

Protector

Compressor

C

M

S

PTC Starter

Starter

S

Impedance coil

Control Enclosure

L
N
E

115V 60Hz

Li

gh

t

 

Summary of Contents for VT-SC-1

Page 1: ...W W W V I N O T E M P C O M A P R O U D H E R I T A G E O F E X P E R I E N C E Q U A L I T Y O W N E R S M A N U A L B e v e r a g e C o o l e r V T S C 1 ...

Page 2: ...n included before discarding any packaging materials You may want to keep the box and packing materials for use at a later date Upon receipt and inspection of unit the supply cord must be replaced if it is damaged Contact our customer service at 1 800 777 8466 or info vinotemp com Let the unit rest UNPLUGGED for 12 hours once you have it placed in your home Please fully read the instruction manual...

Page 3: ...e unit in moist areas Never allow children to operate play with or crawl inside the unit To disconnect the appliance grip the plug and pull it from the wall outlet Never pull by the cord Do not operate the appliance with a damaged cord or plug If the product malfunctions or if it is dropped or damaged in any manner do not use Do not install your cooler in direct sunlight or near a range of heat or...

Page 4: ... the appliance close to walls this could damage the electric cord and may block the air circulation to the appliance Keep the cooler a distance of at least 4 inches from wall Do not block the air intake that ventilates the condenser unit ELECTRICAL CONNECTION This unit operates with a 115V 60Hz power supply Check the electrical outlet for proper voltage Warning Do not plug other electrical applian...

Page 5: ...e the frequency of opening the door during a power failure Most power failures are corrected within a few hours and the temperature of your beverages will not be affected If the power will be off for an extended period proper procedure should be followed for the stored cans Non use for extended time frames If your cooler is unused for extended periods it is best to remove the cans unplug and clean...

Page 6: ...eck that the cooler is level Compressor turns on and off frequently The room temperature is higher than normal The door is not closed completely The door gasket is not sealed well There is insufficient clearance around the cooler The cycling frequency will reduce when all of the cans reach the set temperature The following is not a malfunction It is normal to hear gurgling sounds caused by the flo...

Page 7: ...y is 3 months from your dated invoice parts for function only not cosmetic There is no warranty on parts purchased separately Purchaser s exclusive remedy is limited at Seller s option to repair or replace defective part s with either new or factory reconditioned part s Purchaser is responsible for shipping the unit pre paid to designated facility and Seller will pay return shipping charges in the...

Page 8: ...ase do not place the unit within reach of children For adult use only Contact info vinotemp com with any questions or visit www vinotemp com 17631 S Susana Road Rancho Dominguez CA 90221 www vinotemp com Vinotemp is a registered trademark of Vinotemp International All products features and services are subject to change without notice We cannot guarantee the accuracy of the contents of this docume...

Reviews: