Fig. 7 WM-650~1203SCUR Condensing Unit
Fig. 8 WM-Liquid Filter Fig. 9 WM-Liquid Indicator
2. Temperature Controller and Air Probe Location
1) The temperature controller can be mounted either inside or outside the wine
cellar, but the air probe must be located inside.
2) The air probe shall be located in the wine cellar 5 ft above the floor or the air
return area, but it shall not be located in the air supply area or other areas
where air is not circulated.
3) Air probe can be pulled out of the temperature controller up to 5 ft. If
additional wires are necessary, 18 gauge wires may be used to extend the air
probe.
3. Evaporator Unit Location
Summary of Contents for WINE-MATE WM-12000SSD
Page 2: ...1 Important Safety Information...
Page 17: ...16 Fig 3 Temperature Controller 4 5 L X 4 5 W X 3 75H Fig 4 WM 25 45SFCD Evaporator Unit...
Page 18: ...17 Fig 5 WM 65 120SFCD Evaporator Unit Fig 6 WM 250 450SCUR Condensing Unit...
Page 30: ...29 Fig 19 WM 6500 12000SSD LA Electrical Wiring Diagram...