- 23 - 

repair,  re-pack  it  in  the  original  shipping  carton  and  return  it  to  the  factory,  shipping 

prepaid. VINOTEMP will not accept COD shipments. If the unit is determined to be faulty 

and is within the twelve month warranty period VINOTEMP will, at its discretion, repair 

or replace the unit and return it free of charge to the original retail customer. If the unit 

is found to be in good working order, or beyond the initial twelve month period, it will 

be returned freight collect. 

 

2. Limitation of Implied Warranty 

 

VINOTEMP’S  SOLE  LIABILITY  FOR  ANY  DEFECTIVE  PRODUCT  IS  LIMITED  TO,  AT  OUR 
OPTION, REPAIRING OR REPLACING OF UNIT. 

 

VINOTEMP SHALL NOT BE LIABLE FOR: 

DAMAGE  TO  OTHER  PROPERTY  CAUSED  BY  ANY  DEFECTS  IN  THE  UNIT,  DAMAGES 

BASED  UPON  INCONVENIENCE,  LOSS  OF  USE  OF  THE  UNIT,  LOSS  OF  TIME  OR 

COMMERCIAL LOSS, ANY OUTER DAMAGES, WHETHER INCIDENTAL, CONSEQUENTIAL 

OR OTHERWISE. 

 

THIS  WARRANTY  IS  EXCLUSIBE  AND  IS  IN  LIEU  OF  ALL  OTHER  WARRANTIES, 

EXPRESSED OR INPLIED, INCLUDING BUT NOT LIMITED TO, IMPLIED WARRANTIES OF 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 

               

While  great  effort  has  been  made  to  provide  accurate  guidelines  VINOTEMP  cannot 

warrant its units to properly cool a particular enclosure. Customers are cautioned that 

enclosure construction, unit location and many other factors can affect the operation 

and performance of the unit. There for suitability of the unit for a specific enclosure or 

application  must  be  determined  by  the  customer  and  cannot  be  warranted  by 

VINOTEMP.  

Summary of Contents for WINE-MATE WM-1500LOWP

Page 1: ...lation Use Care Manual Self contained Wine Cooling System WM 1500LOWP WM 1500LOWP TE WM 2500LOWP WM 2500LOWP TE Read and save these instructions Do not plug the unit into power until 24 hours after de...

Page 2: ...pter or an extension cord Do not use a ground fault interrupter GFI Do not under any circumstances cut or remove the third ground prong from the power cord Never unplug the unit by pulling the power c...

Page 3: ...2 Table of Contents Features Specifications 3 Installation Instructions 5 Temperature and Humidity 12 Care Guide 16 Troubleshooting 17 Electrical Wiring Diagram 20 Customer Support 21 Warranty 22...

Page 4: ...zed for long term storage of wine Temperature is controlled and humidity is adjusted using patented technology Larger bottom cold air supply provides more even temperature distribution in the wine cab...

Page 5: ...90 115V 60Hz 3A 55 WM 2500LOWP Rear 24 1 4 x 15 1 8 x 7 1 2 180 200 115V 60Hz 4A 60 WM 2500LOWP TE Top 24 1 4 x 15 1 8 x 7 1 2 180 200 115V 60Hz 4A 60 NOTE See the voltage frequency and current speci...

Page 6: ...unit will build up and it may cause the cooling unit not to work properly The exhaust area must not be closed space and must be ventilated The ambient temperatures shall not be higher than 78 F for ru...

Page 7: ...n in Fig 2 1 If it is a top exhaust installation make another rectangular hole at the top of the cabinet with the length and width of the top exhaust as shown in Fig 2 2 Install 2 pieces of 1 4 ID woo...

Page 8: ...7 Fig 2 2 Top Exhaust Cutouts Fig 2 3 Installing Screw Inserts Fig 2 4 Installing Rear Gaskets Fig 2 5 Installing Top Gaskets 16 Top Gasket...

Page 9: ...8 Fig 2 6 Installing Cooling Unit...

Page 10: ...9 Fig 2 7 Cooling Unit Installed Rear Exhaust Rear Exhaust Ambient Air Intake...

Page 11: ...10 Fig 2 8 Cooling Unit Installed Top Exhaust Top Exhaust Ambient Air Intake...

Page 12: ...11 Fig 2 9 Cooling Unit Installed Low Front Grille Top Exhaust Cover Low Front Grille Ambient Air Intake...

Page 13: ...k the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock the keys pres...

Page 14: ...e at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of bottles temperature setting and surrounding temper...

Page 15: ...ay min 10 Con compress on with probe faulty min 20 CoF compress off with probe faulty min 20 CF temperature unit F C F Fahrenheit rES display resolution in integer dLy temperature display delay min 1...

Page 16: ...idity Use a separate hygrometer to monitor the humidity 10 How to set alarm call 1 Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the set point S...

Page 17: ...take side of the cooling unit Use a condenser brush or a vacuum cleaner with an extended attachment to clean the condenser 2 Removing Condensate Remove the excessive condensate if it is accumulated on...

Page 18: ...g an air probe the wine bottle temperature is mainly controlled by the average air temperature If the set point is 55 F with the differential 4F the cooling unit turns on at 59 F of air temperature It...

Page 19: ...ulation gasket and door opening power cord grommet b Check for excessive size c Check for installation location d Leave minimum 3 feet clearance for the hot air exhaust side and leave minimum 1 foot c...

Page 20: ...ndensate b High humidity causing excessive condensate c Evaporator air flow restriction d Water passages restricted e Drip tray leak No water overflow but water leak a Check for air leak b Use drain l...

Page 21: ...20 Electrical Wiring Diagram Fig 6 1 Wiring Diagram...

Page 22: ...21 Customer Support If you need further assistance please contact us at Vinotemp International Corp 732 S Racetrack Rd Henderson NV 89015 Tel 310 886 3332 Fax 310 886 3310 Email info vinotemp com...

Page 23: ...hs after initial sale This warranty constitutes the entire warranty of the VINOTEMP with respect to its products and is in lieu of all other warranties express or implied including any of fitness for...

Page 24: ...LIABLE FOR DAMAGE TO OTHER PROPERTY CAUSED BY ANY DEFECTS IN THE UNIT DAMAGES BASED UPON INCONVENIENCE LOSS OF USE OF THE UNIT LOSS OF TIME OR COMMERCIAL LOSS ANY OUTER DAMAGES WHETHER INCIDENTAL CONS...

Reviews: