-18-
Fig. 6 WM-250~850SCUR-WC Condensing Unit
Fig. 7 WM-Liquid Filter
Fig. 8 WM-Liquid Indicator
2. Temperature Controller and Air Probe Location
1) The temperature controller can be mounted either inside or outside the wine
cellar, but the air probe must be located inside.
2) The air probe shall be located in the wine cellar 5 ft above the floor or the air
return area, but it shall not be located in the air supply area or other areas
where air is not circulated.
3) Air probe can be pulled out of the temperature controller up to 5 ft. If additional
wires are necessary, 18 gauge wires may be used to extend the air probe.
3. Evaporator Unit Location
1) The WM-25~85SFCL evaporator units shall be installed for ceiling mount with
the supply air toward horizontal and return air on the bottom. The units may