-15-
Installer’s Instructions
WARNING
•
Always check wiring harness connections before initiating any test procedures.
•
Disconnect electric power from the appliance before performing any
maintenance or repairs.
•
Voltage checks should be made by inserting meter proves beside the wires in
the connector blocks with the electric power source on and the connector block
plugged in.
•
Resistance checks should be made on components with the electric power off
and the connector block disconnected.
Federal law requires that WINE~MATE split cooling systems be
installed by an EPA certified refrigeration technician.
1. General Instructions
WINE~MATE split system is shipped as components and is ready for use only after
a certified refrigeration technician has properly installed the system. Proper
installation is critical. Vinotemp can only warrant the quality of the components. The
installation and proper operation of the system must be warranted by the installer.
Installation of the system must be done in accordance with all state and local
building and electrical codes.
The condensing unit and evaporator unit are connected by a liquid line and an
insulated suction line that are supplied by the installer. These lines must be properly
sized for the distance between the two units. After the units and lines are
connected, the system must be checked for restriction, pressurization and leak.
Then the system must be evacuate and charged with refrigerant. Refrigerant
amount will vary depending on the length of line set.
Parts included:
Temperature Controller
Evaporator Unit (liquid line solenoid valve and expansion valve are installed)
Condensing Unit (discharge, suction valves and pressure controls are installed)
Liquid Filter
Liquid Indicator
WARNING
Do not use a ground fault interrupter (GFI). A
dedicated circuit is required.
Summary of Contents for WINE-MATE WM-2520SSL
Page 18: ...17 Fig 3 Temperature Controller 4 5 L X 4 5 W X 3 75H...
Page 19: ...18 Fig 4 WM 252SFCL Evaporator Unit Fig 5 WM 452 852SFCL Evaporator Unit...
Page 20: ...19 Fig 6 WM 252 452SCUR Condensing Unit Fig 7 WM 652 852SCUR Condensing Unit...
Page 31: ...30 Fig 19 WM 6520 8520SSL LA Electrical Wiring Diagram...