-20-
Fig. 8 WM-Liquid Filter
Fig. 9 WM-Liquid Indicator
2. Temperature Controller and Air Probe Location
1) The temperature controller can be mounted either inside or outside the wine
cellar, but the air probe must be located inside.
2) The air probe shall be located in the wine cellar 5 ft above the floor or the air
return area, but it shall not be located in the air supply area or other areas where
air is not circulated.
3) Air probe can be pulled out of the temperature controller up to 5 ft. If additional
wires are necessary, 18 gauge wires may be used to extend the air probe.
3. Evaporator Unit Location
1) The WM-252~852SFCL evaporator units shall be installed for ceiling mount with
the supply air toward horizontal and return air on the bottom. The units may be
recessed in the ceiling with short curved rectangular ducts in air supply, but the
air flow CFM must be checked.
2)
For a direct blow application, air supply shall be unobstructed minimum 12”.
For a deflector application, leave
2” clearance for air supply.
Air return shall be unobstructed minimum
6”.
3) There is a gravity drain system, so the unit shall be installed level or with a slight
slope downward the drain connection and the drain line shall be installed slope
down toward the drain.
If rise-up is necessary, a condensation pump must be used.
4. Condensing Unit Location
CAUTION
Low ambient condition kit is required if the temperature will be
below 50
°
F.
Summary of Contents for WINE-MATE WM-2520SSL
Page 18: ...17 Fig 3 Temperature Controller 4 5 L X 4 5 W X 3 75H...
Page 19: ...18 Fig 4 WM 252SFCL Evaporator Unit Fig 5 WM 452 852SFCL Evaporator Unit...
Page 20: ...19 Fig 6 WM 252 452SCUR Condensing Unit Fig 7 WM 652 852SCUR Condensing Unit...
Page 31: ...30 Fig 19 WM 6520 8520SSL LA Electrical Wiring Diagram...