-6-
Temperature and Humidity
1. The controller
Fig. 2 TEMPERATURE CONTROLLER
1) Keys
SET:
To display set-point; in programming mode it selects a parameter or
confirms an operation.
:
To start a manual defrost.
:
To see the maximum stored temperature; in programming mode it browses
the parameter codes or increases the displayed value.
:
To see the minimum stored temperature; in programming mode it browses
the parameter codes or decreases the displayed value.
:
To turn on/off the power to the unit.
+
:
To lock/unlock the keypad.
SET+
:
To enter in the programming mode.
SET+
:
To return to the temperature display.
2) Lock and unlock the keys
To lock the keys, press up + down keys
+
until POF is displayed; to unlock
the keys, press up + down keys
+
until PON is displayed.
3) Display
During normal operating conditions, the display shows the value measured by the
air temperature probe. In case of active alarm, the temperature flashes alternately
to the code alarm. The LED functions are listed as follows.
LED
MODE
FUNCTION
ON
Compressor enabled
Flashing
Anti-short cycle enabled
ON
Defrost enabled
ON
Fan enabled
Flashing
Fan delay after defrost enabled
ON
Alarm occurring
ON
Temperature measuring unit
Flashing
Programming mode
Summary of Contents for WINE-MATE WM-2520SSL
Page 18: ...17 Fig 3 Temperature Controller 4 5 L X 4 5 W X 3 75H...
Page 19: ...18 Fig 4 WM 252SFCL Evaporator Unit Fig 5 WM 452 852SFCL Evaporator Unit...
Page 20: ...19 Fig 6 WM 252 452SCUR Condensing Unit Fig 7 WM 652 852SCUR Condensing Unit...
Page 31: ...30 Fig 19 WM 6520 8520SSL LA Electrical Wiring Diagram...