TROUBLE SHOOTING
1
WINEMATE
COOLING SYSTEMS ARE SEALED SYSTEMS THAT REQUIREDS A MINIMUM
OF SERVICE.
WARNING
:
UNPLUG UNIT BEFORE CLEANING
2
CLEAN THE EXHAUST GRILL AT LEAST 3-4 TIMES A YEAR.(RECOMMENDED WITH VACUUM)
3
THE UNIT MAY RUN CONSTANTLY OR CYCLE ON AND OFF FOR SHORT PERIODS.
4
THE TIME REQUIRED TO REACH THE DESIRED TEMPERATURE WILL VARY, DEPENDING
ON THE ENCLOSURE CONSTRUCTIONS AND CONTENTS.
5
WINEMATE
COOLING SYSTEM ARE NOT FOR USE BELOW 50F. AND WORK BEST AT 55F
TO 60F
PROBLEM
CHECK
REMEDY
NOT RUNING
POWER TO OUTLET
RESET CIRCUIT BREAKER
IS WINE CELLAR PLUGGED IN
PLUG IN
IS UNIT PLUG IN
PLUG IN INSIDE OF WINE CELLAR
IS THERE DF DISPLAY ON DIGITAL
UNIT IN DEFROST 30 MIN MAX
CHECK FOR 15 MIN.& SEE IF UNIT ITS CYCLE WORKING NORMAL
STILL DOES NOT START
CALL SERVICE
RUNNING WARM
UNIT TURNS ON ON OFF
ADJUST DIGITAL TO COLDER STTING
RUNS ALL THE TIME
IS CONDESOR DIRTY
CLEAN CONDENSOR
IS UNIT ICED UP
DEFROST AND CHECK FOR AIR FLOW
OR ITS SET TO COLD
PROPER CLEARANCE FROM WALL
EXHAUST 6" FROM WALL ALL AROUND
CHECK WINE CELLAR FOR AIR LEAKS
REPAIR AIR LEAKS
STILL RUNS WARM
CALL SERVICE
RUNNING TO COLD
UNIT TURNS ON AND OFF
ADJUST DIGITAL TO WARMER SETTING
STILL RUNS TO COLD
CALL SERVICE
EXCESS MOISTURE
CHECK WINE CELLAR FOR AIR LEAKS AND
REPAIR AIR LEAKS OR SEAL DOORS
IN WINE CELLAR
DOORS SEALS
PAGE 3