background image

ALIGNING THE DOORS

To assure the best performance of this product, the doors must
seal properly in order to prevent cool air from escaping the
unit.

It will be vitally important to check the proper alignment of the
doors when the unit is in its permanent location and prior to
filling it with wine.

If adjustments are needed: 

Compensate for this problem by adjusting the two fronts and/or

the outside legs. This should make the proper alignments. The high side should be adjusted
up while the low side should be adjusted down. Rock the unit side to side as it may aid the
adjustment process.

On a single door unit as you face the cabinet, check to see if the door is higher than the
cabinet. If so, adjust the left front leg. Lowering the left front leg will raise the right front.

Aligning the Doors

-9-

high side

front view

single door unit

front view

2-door unit

h

igh side

Summary of Contents for Wine Cellars

Page 1: ...Owner s Manual Protecting Your Investment in Fine Wines...

Page 2: ......

Page 3: ...mployees plays an integral role in this process Your unit has been created especially for you based on the information received from our distributor We hope you enjoy the cabinet for years to come wit...

Page 4: ...ting Instructions 12 QT Series Operating Switches 13 WhisperKool Series Operating Switches 14 Monterey Credenza Operating Switches 15 Testing the Refrigeration Unit 15 Loading Bottles 16 Cool Down Per...

Page 5: ...IS HIGHLY RECOMMENDED FOR OPTIMUM OPERATION Do not use a Ground Fault Interrupter GFI with this product The cooling unit will draw more amperage than the GFI will allow Upon plugging the unit in QT s...

Page 6: ...specific instructions for the installers to follow to assure they understand all variables associated with handling this product and meet the expectations set forth Their instructions include the foll...

Page 7: ...any potential damage is noted have the packaging removed and inspect those areas closely Specifically inspect the compressor pan on the QT series cabinets It is located at the bottom rear of the unit...

Page 8: ...C Ventilation factor Ventilation is an important factor to consider when choosing the correct location The compressor motor will give off heat which will need to dissipate away from the unit If the u...

Page 9: ...units The first is to assure that the unit stands solidly on the floor without rocking back and forth The second is to adjust the doors to assure that they are flush and provide a tight seal The level...

Page 10: ...te for this problem by adjusting the two fronts and or the outside legs This should make the proper alignments The high side should be adjusted up while the low side should be adjusted down Rock the u...

Page 11: ...l a surge protector for the unit itself 4 Fahrenheit and Celsius readout The thermostat has the ability to produce the readout in both Fahrenheit and Celsius for overseas customers The readout can be...

Page 12: ...connected to the thermostat Buttons To change the set point temperature press either the or button The SET light will flash once for each 1 F the set point is changed This set point will remain in mem...

Page 13: ...the unit to maintain 7 UP Arrow Button Used with the SET button to set temperature higher In addition by pressing and holding the button it will allow you to see the 5 minute count down 8 DOWN Arrow B...

Page 14: ...cated in a dry climate there is a good chance that the unit will not accumulate excessive water Therefore elect to save electricity by setting the Condensate Evaporator to the OFF position Temperature...

Page 15: ...inoth que units are equipped with sophisticated heating elements that automatically sense the presence of water and work continually until the water is gone Setting the condensate evaporator to the On...

Page 16: ...ll bottle capacity while not adding any significant enhancement to the credenza TESTING THE REFRIGERATION UNIT Do not start or plug in your unit for 24 hours after delivery Many units are placed on th...

Page 17: ...oors out of alignment In the QT Series there s an auxiliary section on the bottom for odd size bottles On the WhisperKool Series there s auxiliary racking on top Loading Bottles Cool Down Period COOL...

Page 18: ...ity requires In areas of high humidity leave the switch On to evaporate excess condensation In environments of low humidity leave the switch in the Off position Temperature Equalizer Turn on whenever...

Page 19: ...reach optimal storage temperature Ambient room temperature Units cool 30 degrees below ambient may need to run Inadequate ventilation Assure proper space above behind on side of unit Do NOT stack any...

Page 20: ...act Customer Service If the thermostat is operating incorrectly contact Customer Service for a replacement DOOR GASKET NOT SEALING CORRECTLY If the cabinet s cooling system is running continually with...

Page 21: ...tation or after installation in an ambient environment substantially dryer or substantially more humid than that in which the unit was manufactured and packaged with the door s closed only exterior pa...

Page 22: ...t the condition after treatment Vinoth que is not responsible for reversible moisture induced warpage of unfinished doors or for door stained and or sealed after shipment from the factory FREIGHT DAMA...

Page 23: ...sts 1200 650 100 750 2300 670 100 770 California customers add sales tax on parts Upon receiving your Factory Authorized Replacement order you will be provided an RMA Return Merchandise Authorization...

Page 24: ...es not cover cosmetic damage caused during installation or damage due to acts of God accident misuse abuse negligence commercial use or modification of or to any part of the Product This warranty does...

Page 25: ...rk of distributors These distributors are trained to be your primary resource for all customer service situations Through the sales process they have developed a thorough understanding of the environm...

Page 26: ......

Page 27: ......

Page 28: ...1738 East Alpine Avenue Stockton California 95205 www vinotheque com...

Reviews: