User's Manual
Arctic Communication Gateway
Firmware Version 3.1.5
18
Document Version 1.0
3. Enter the username and password and press Login button in the log-in
screen. The actual screen depends on the used web browser.
Note!
Default username is
viola-adm
and default password is
violam2m
. It is
recommended that the default password is changed before the product is
connected to a public network.
4. White texts on the blue background on the left are the primary navigation
texts and they are always visible on the screen. Individual screens may
have their own tabs which split the configuration fields on larger screens.
See the figure below.
Figure 10. Configuration menu
3.4
Setting Ethernet port function to LAN
Disable automatic IP address detection by changing the port function to LAN.
If the Port function is at the default setting of auto, the Ethernet LAN port
tries to automatically obtain the IP address using DHCP when the device
boots. If the DHCP discovery fails, the Arctic automatically uses IP address
10.10.10.10.