Appendix B - Overview: 7700 FSP Controller
120
7700 Flash Storage Platform Installation Guide 7.6.3.x
530-0267-00 Rev 02
Note:
To reference the specific physical locations for both the Fibre Channel and iSCSI HBA slots
and port numbers, see Figure 2.1 (Fibre Channel) and Figure 2.2 (iSCSI).
Table B.3 describes the status LEDs for the 7700 FSP Controller power supplies.
Monitoring 7700 FSP Controllers Using iDRAC
The IPMI/iDRAC support in the 7700 FSP Controllers provides system power control that supports
a standard Web browser and a Virtual Console with a standard Web browser with Java support.
iDRAC supports SNMP, IPMI, remote logging, and SMTP e-mail alerts (for more details, see the
latest Dell iDRAC documentation at
http://www.Dell.com
).
Symphony and the Concerto OS use IPMI monitoring and control for access and power control, and
use iDRAC to monitor other important system components such as system disks, fans, and
temperature. If your data center already supports Dell iDRAC, add each 7700 FSP Controller’s
iDRAC to your management infrastructure.
Note:
Do not upgrade iDRAC, the System BIOS, or system firmware used on the 7700 FSP
Controllers without first consulting Violin Support.
Log in to the iDRAC Virtual Console on each 7700 FSP Controller to inspect current status and/or
modify management or monitoring settings by using the default login credentials set by Violin
Systems:
admin
and
violin101
(for a log in example, see
Note:
Because Symphony does not directly monitor the 7700 FSP Controllers in the 7700 FSP
storage cluster, use iDRAC to monitor the system status for 7700 FSP Controller components.
iDRAC supports SNMP, IPMI, remote logging, and SMTP mail alerts. For more details on setting up
and using iDRAC, see the following subsections in this appendix.
LED Display
Description
unlit
Indicates that no AC power going to the power supply.
green
Indicates that the power supplies are operating normally.
blinking green
Indicates that the power supplies are not the same type.
blinking amber
Indicates that a problem has been detected on the power supply.
Table B.3 7700 FSP Controller Power Supply Status LEDs