Chapter 1   Hardware description

 

Manual VIPA HMI 

1-4 

 

HB160E - TP - RE_62F-FCB0 - Rev. 11/14 

Structure 

 

 

 

[1] Slot for storage medium  

(CF, SD/MMC) 

[2] Connection for interfaces and 

power supply 

T

o

uc

h P

a

ne

l

1

2

3

 

[3] Display with touch sensitive area 

(touch screen) 

 

 

 

[1] Compact Flash 
[2] MMC / SD 

1

2

 

 

 

 

Note! 

Please only use storage media, which are tested and approved by VIPA 
GmbH. 
 
 

Front view 

Side view 

    

 

All manuals and user guides at all-guides.com

Summary of Contents for 62F-FCB0

Page 1: ...VIPA HMI Touch Panel 62F FCB0 Manual HB160E_TP RE_62F FCB0 Rev 11 14 April 2011 All manuals and user guides at all guides com...

Page 2: ...ve 2006 95 EC Low Voltage Directive Conformity is indicated by the CE marking affixed to the product Conformity Information For more information regarding CE marking and Declaration of Conformity DoC...

Page 3: ...sioning 2 4 Connection to a PLC system 2 12 Operating system Windows CE 5 0 2 13 Communication via ActiveSync 2 19 Integrated Server 2 21 Access to the network resources 2 28 Firmware update 2 30 Chap...

Page 4: ...Contents Manual VIPA HMI ii HB160E TP RE_62F FCB0 Rev 11 14 All manuals and user guides at all guides com...

Page 5: ...chapter closes with the technical data Chapter 2 Deployment Touch Panel This chapter deals with the application of the Touch Panel At the beginning of the chapter you get information about the assemb...

Page 6: ...hapter The manual is available in printed form on paper in electronic form as PDF file Adobe Acrobat Reader Button Buttons are put in brackets e g NEXT or OK Key Key entry are put in brackets e g STRG...

Page 7: ...manual must be available to all personnel in the project design department installation department commissioning operation The following conditions must be met before using or commissioning the compo...

Page 8: ...Safety information Manual VIPA HMI 4 HB160E TP RE_62F FCB0 Rev 11 14 All manuals and user guides at all guides com...

Page 9: ...ides of a description of the single components of the Touch Panel you will also find the dimensions that are required for the installation The chapter closes with the technical data Topic Page Chapter...

Page 10: ...to become inoperable or unusable Modules that have been damaged by electrostatic discharges may fail after a temperature change mechanical shock or changes in the electrical load Only the consequent i...

Page 11: ...ontrolling of process cycles Windows CE 5 0 Core Different HMI SCADA Runtime selectable 520MHz pulse frequency Work memory 64Mbyte about 6Mbyte memory for user data on board CF Card II and MMC SD card...

Page 12: ...medium CF SD MMC 2 Connection for interfaces and power supply T o u c h P a n e l 1 2 3 3 Display with touch sensitive area touch screen 1 Compact Flash 2 MMC SD 1 2 Note Please only use storage medi...

Page 13: ...DP RS485 interface 4 Host USB A interface 5 Slave USB B interface 6 RJ45 jack for Ethernet communication 7 Slot for DC 24V voltage supply 8 Slot for CF SD MMC storage medium Note Please regard that t...

Page 14: ...ou may plug a CompactFlash type II The card may be plugged and removed during runtime and is immediately listed as Storage Card at My Device Every CompactFlash storage module has a pulling edge Hold t...

Page 15: ...9 8 7 6 9 RxD Line B TxD A TxD B RxD A RxD B Shield RS422 Periphery 3 8 4 9 M5V TxD TxD RxD RxD P5V 5 6 Serial bus connection in 2 wire technology using half duplex mode Connection RS485 isolated TxD...

Page 16: ...Connection RS232 9pin plug Connection RS232 Pin RS232 1 CD 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 1 2 3 4 5 6 7 8 9 9 RI RxD TxD GND TxD RxD 3 2 GND 5 RTS CTS 7 8 Shield RS232 Periphery Shield An...

Page 17: ...SB B Pin Assignment 1 VCC 2 DM 3 DP 2 1 3 4 4 GND The USB A interface of your PC can be connected to the Slave USB B interface of your Touch Panel deploying the USB programming cable The USB programmi...

Page 18: ...t panel W x H 212 x 156mm Display size W x H 115 2 x 86 4mm Back side W x H x D 198 x 142 x 37mm Installation depth 37mm Note The degrees of protection are only guaranteed when the following is observ...

Page 19: ...reen resistive Keyboard external via USB Mouse external via USB Interfaces MPI PROFIBUSDP RS485 isolated MPI PROFIBUSDP connector Sub D 9 pin female CAN CAN connector Serial COM1 RS232 COM1 connector...

Page 20: ...ide IP 65 Protect type back side IP 20 Dimensions Front panel 212 x 156 x 7 5 mm Rear panel 198 x 142 x 37 mm Installation cut out Width 200 mm Height 144 mm Minimum 2 5 mm Maximum front panel thickne...

Page 21: ...of the Touch Panel The main part of the chapter introduces Windows CE and the various communication options offered by the Touch Panel Topic Page Chapter 2 Deployment Touch Panel 2 1 Installation 2 2...

Page 22: ...into a operating tableau and control cabinet fronts the Touch Panel requires the following front plate cutting W H Touch Panel W x H in mm 62F FCB0 200 x 144 The fixing technique is integrated in the...

Page 23: ...t end case as well as stiff wires Fix the conductors to the CageClamps like this DC 24V 1 2 3 1 Round opening for wires 2 Locking orange for screwdriver 3 Test point for 2mm test tip 1 2 3 The picture...

Page 24: ...l cables must not be let within the same cable shaft as high voltage cables As soon as the Touch Panel is provided by power supply the Touch Panel starts with user area of the VIPA Startup Manager On...

Page 25: ...es may be restored by Restore Here you get information about Touch Panel like operating system images runtime version and tools With this button you may return to the user area With the button Control...

Page 26: ...ated With disabling Run on Startup the Touch Panel starts with the Windows operating system The functions preset at Settings are ignored With enabling Enable User Interface the Touch Panel starts with...

Page 27: ...administrator area Here new buttons may be configured and assigned with corresponding programs You may choose Normal for the user area or Advanced for the administrator area With a new button may be a...

Page 28: ...re prompted to enter the password If there is no password defined the administrator area is opened On delivery there is no password preset If you have forgot you password by enabling the checkbox Show...

Page 29: ...corresponding file is removed from the list With the file may be downloaded With Autostart a program from the program list can be selected which is to be started delayed For this activate Autostart an...

Page 30: ...start via the button Control Panel the tool Com2 Configuration In the opened dialog window you activate the RS485 or the RS422 interface Default off To remain the settings permanently they have to be...

Page 31: ...ovicon or zenon Via mode the interface could be set up on DP Slave Note It is possible to set up the DP slave with the tool via software but the hardware of the Touch Panel doesn t support this In thi...

Page 32: ...HMI SCADA project engineering platforms your project is run able By using the according communication driver the Touch Panel supports connecting options to the PLC via MPI field bus and Ethernet Durin...

Page 33: ...open and scalable platform for a multiplicity of communication and data processing devices The functions like multi tasking and multi threading are supported by this operating system Windows CE 5 0 C...

Page 34: ...xecutes this Drag By tapping on an object and then dragging you may move the object on the screen If no object is selected a frame is created by the dragging that selects the touched objects The windo...

Page 35: ...omponents of your Touch Panel like e g applications system settings file browser etc 2 Open applications For every open application a button is to be found in the task bar There is no button for minim...

Page 36: ...e software keyboard Keyboard Normal At pushed SHIFT key Meaning Home Position 1 End End BS Backspace up dn lt rt pgup Page pgdn Page ins Insert del Delete Tab Tabulator Shift Caps Lock The software ke...

Page 37: ...may use the grid pattern to preset a double click velocity and test this on the symbol below OK takes over the set value The calibration of the touch screens happens via the register Calibration by fo...

Page 38: ...Rate Enter here the transfer velocity of your MPI net The baud rate has to be identical for every MPI participant within the network According to the Baud Rate the network parameters are set Default N...

Page 39: ...u may access the Touch Panel from the PC via ActiveSync you have to install it on the PC ActiveSync is freeware and may be downloaded from www microsoft de Download the ActiveSync from the Microsoft w...

Page 40: ...zed and the dialog window new partnership opens Choose yes for fixing a partnership and push Next In the now opening window de activate all synchronization settings and click on Next Finish establishe...

Page 41: ...ools before switching off Per default the following server are integrated ftp server activated http server activated Telnet activated VNC not activated Phrases that are used in the description of the...

Page 42: ...e are still problems with the ftp access please ask your system administrator ftp access possible with version 5 5 or higher use passive ftp mode activate directory view for ftp sites For the adjustme...

Page 43: ...he network where your PC is a member via an Ethernet cable Switch on your Touch Panel As soon as your Touch Panel is connected via Ethernet you may monitor the IP address data via After you ve confirm...

Page 44: ...dress webadmin Enter the following into the authentification User name wince Password vipatp Remember to store your changes permanently in the registry via Start Programs KuK_Tools KuK Tools Store Sys...

Page 45: ...The establishing of a Telnet connection is password protected and has the following approach Start a Telnet client like for example MS DOS console at your PC and enter the following into the address...

Page 46: ...stablishment of a Telnet connection the Touch Panel provides you with commands A list of possible commands with a short description is available via the command help By beginning with help before a co...

Page 47: ...n the Windows directory You have to deactivate every option at View Options to show the VNC server file Start the VNC server by executing the file winvnc exe To show the server has been started the sy...

Page 48: ...ical connection a PING to the IP address of the network PC may be executed if there are problems while contacting the network PC The connection of a local name at the Touch Panel with a shared drive o...

Page 49: ...le you may print the content of the current directory using dir network printer The listing command for all network connections of your Touch Panel is net use You may terminate already assigned networ...

Page 50: ...bH Go to www vipa de Click at Service Support Downloads Firmware and navigate via HMI to the firmware for your Touch Panel Transfer the os file to your PC Copy the file to your storage medium Switch o...

Page 51: ...ble paths how interference can enter the controller how you ensure the electromagnetic compatibility EMC and how to approach shielding and screening issues Topic Page Chapter 3 Installation Guidelines...

Page 52: ...and complies with EMC requirements to a large degree In spite of this you should implement an EMC strategy before installing any components which should include any possible source of interference El...

Page 53: ...ge of the voltage Interference through parallel signal lines Static discharge of the personnel Contactors Inductive coupling Automation System Disruptor inductive coupling line wanted signal Inductive...

Page 54: ...s power supply lines signal lines data lines Always install high voltage lines and signal or data lines in separate channels or bundles Install signal and data lines as close as possible to any metall...

Page 55: ...gle reference potential and ensure that all electrical equipment is grounded wherever possible Ensure that grounding measures are implemented effectively The controllers are earthend to provide protec...

Page 56: ...in case of an error The ground must not adopt dangerous contact voltage even in case of an error Thus you have to connect the ground with the protected earth conductor To avoid ground loops local dist...

Page 57: ...different groups and install each group itself Group A screened bus and data lines screened analog lines unshielded lines for direct voltage 60V unshielded lines for alternating voltage 25V Coaxial c...

Page 58: ...c cable trays A galvanic connection must be provided for joints between cable trays You must abide by the applicable lightning protection and grounding regulations when installing exterior cables Atte...

Page 59: ...l bonding conductors up to 200m 25mm2 Cu for equipotential bonding conductors exceeding 200m Use copper or galvanized steel for equipotential bonding conductors These must be connected to ground neutr...

Page 60: ...emove the insulation from the screened cable without cutting the screen and to attach this point to the screening neutral rail Note Potential differences can give rise to an equalization current via t...

Page 61: ...inductors Connections of AC activated inductors using a diode using a Z diode using a varistor using RC network Every cubicle must be provided with a power outlet for the PU These outlets must be wir...

Page 62: ...he connection been protected from corrosion e g by means of grease Have doors been grounded by means of grounding straps connected to the body of the cubicle Cable routing Cabling divided into groups...