Chapter 2 Decentral block periphery CAN-Bus CANopen
Manual VIPA System 100V
2-30
HB100E - SM-CAN - Rev. 15/02
Index
Sub
index
Name
Type
Attr. Map.
Default value Meaning
0x1005
0 COB-Id
sync
message
Unsigned32 ro
N
0x80000080
Identifier of the SYNC
message
The lower 11 bit of the 32-Bit value contain the identifier (0x80=128dez),
the MSBit shows if the device receives the SYNC telegram (1) or not (0).
Attention: In opposite to the PDO identifiers the set MSB signalizes that this
identifier is relevant for the node.
Index
Sub
index
Name
Type
Attr. Map.
Default value Meaning
0x1006
0 Communication
cycle period
Unsigned32 rw
N
0x00000000
Maximum length of the
SYNC interval in µs.
If a value different from Zero is entered here, the coupler switches into error
state, when it doesn't receive a SYNC telegram during the "Watchdog time"
at synchronous PDO operation.
Index
Sub
index
Name
Type
Attr. Map.
Default value Meaning
0x1007
0 Synchronous
window length
Unsigned32
rw
N
0x00000000
Contains the length of time
window for synchronous PDOs
in µs.
Index
Sub-
index
Name
Type
Attr. Map.
Default value Meaning
0x1008
0 Manufacturer
device name
Visible string ro
N
Device name of the bus
coupler
VIPA 153-xxxxx = VIPA CANopen slave 153-4CF00
VIPA CANopen slave 153-4CH00
VIPA CANopen slave 153-6CH00
VIPA CANopen slave 153-6CL10
For the returned value is larger than 4Byte, the segmented SDO protocol is
used for transmission.
SYNC identifier
SYNC interval
Synchronous
Window Length
Device name