56
Printer Maintenance
Replacing the Aerosol Fan Filter
You can replace the aerosol fan guard or just replace the fan filter.
Figure 12
Aerosol fan guard
1. Remove the printer’s side panel.
2. Disconnect the power cable.
3. Carefully remove the four screws at the corners of the fan guard. The fan guard
can then be removed.
4. Align the new fan guard with the mounting holes and replace the screws.
5. Reconnect the power cable.
6. Replace the side panel.
Tools
• Nitrile powder-free gloves
• T20 screwdriver
filter
cover
aerosol fan guard
slot