Table of Zones
Zone No. Trigger type
Input description
1
Instant
H1/6 BLUE - Connect to optional hood/trunk
pins.
2
On-board shock sensor
Heavy impact detected by the on-board shock
sensor.
3
Two-stage, progresses from Door switch circuit. H1/5 GREEN or H1/7
VIOLET warning to full alarm
4
Multiplexed Input
BLUE and GREEN wires of optional sensor
plug. Inputs shorter than 0.8 seconds will trigger
a Warn Away response, while inputs longer than
0.8 seconds will instantly trigger a full alarm
sequence and report Zone 4.
5
Two-stage (similar to doors) Ignition input. H1/9 YELLOW.
NOTE: The Warn Away® response does not report on the LED.
Long Term Event History
The system stores the last two full triggers in memory. These are not erasable.
Each time the unit sees a full trigger, the older of the two triggers in memory
will be replaced by the new trigger. To access long term event history:
1. With the ignition off, press and HOLD the Valet/Program
switch.
2. Turn on the ignition.
3. Release the Valet/Program switch.