background image

   

TC-9 Viper ™ Gate System 

Residential Sliding Gate Operator 

 

23 

Limited Warranty 

 

You must read, understand and agree with items in the Limited 

Warranty. 

 

GATEMOTORS INC. Warrants the 

Sliding Gate Operator to be free of 

defects in workmanship and materials for a period of 1 year for electronics, mechanical 
components and chassis for perforation due to corrosion and 2 year warranty on motor. 
 
GATEMOTORS INC reserves the right of final determination as to the existence and 
causes of any defect or failure. Any part or parts found to be defective and are returned to 
GATEMOTORS INC within the warranty period, shall at our option be repaired or 
replaced free of charge F.O.B. the factory. 
 
The warranty will not apply the following circumstances, which are considered beyond 
our control. Mis-use, vandalism, accident, neglect, unauthorized repairs or modifications, 
acts of God (lightning, floods, insect damage, etc..), power surges, units subjected to 
corrosive environments, incorrect installation or application, damage to mechanism due 
to wrong type of gate, incorrect weight, gate not operating freely or not on level ground. 
 
The warranty set forth above is entirely exclusive and no other warranty whether written 
or oral, is expressed or implied. GATEMOTORS INC. specifically disclaims any and all 
implied warranties, merchantability or fitness for a particular purpose. It is the  
purchaser’s sole and exclusive responsibility to determine whether or not the equipment 
will be suitable for a particular purpose. In no event shall GATEMOTORS INC. be held 
liable for direct, indirect, incidental, special, consequential damages or loss of profits 
whether based on contract, tort, or any other legal theory during the course of the 
warranty or at any time there after. The installer and/or end user do agree to assume all 
responsibility for all liability in use of this product, releasing GATEMOTORS INC. of all 
liability.

 

IN ORDER TO INSTALL AND USE THE

 SLIDING GATE 

OPERATOR, YOU MUST UNDERSTAND AND BE IN FULL UNCONDITIONAL 
AGREEMENT WITH ALL STIPULATIONS OUTLINED ABOVE. IF YOU ARE 
NOT IN FULL AGREEMENT, DO NOT PUT UNIT INTO OPERATION. IF 
OPERATOR IS PUT INTO OPERATION THIS WILL BE CONFIRMATION 
THAT YOU ARE IN FULL UNCONDITIONALL AGREEMENT WITH ALL OF 
THE ABOVE STIPULATIONS.

 

 

25

Summary of Contents for TC-9

Page 1: ...tor intended for use in a single family dwelling Made in the U S A CAUTION PLEASE READ THIS MANUAL CAREFULLY GATEMOTORS INC PHONE 352 241 8259 Email Sales Vipergatesystems com This Product meets and e...

Page 2: ...TC 9 Viper Gate System Residential Sliding Gate Operator This page intentionally left blank 2...

Page 3: ...trical Installation 12 Radio Transmitter Controls 15 Optional Equipment Installation Procedures 20 Adjustment and Maintenance 21 Having a Problem 22 Figure 1 Platform Base Dimensions 9 Figure 2 Viper...

Page 4: ...vide power be sure to attach the ground conductor to the TC 9 Frame and the ground terminal on the circuit board Caution Activate the opener only when the gate is in full view and free of obstructions...

Page 5: ...lectronic anti entrapment system operable in both the open and closing directions Enclosed chain cover for added protection SPECIFICATIONS Table 1 Viper TC 9 Specification Motor Safety Type Permanent...

Page 6: ...TC 9 TC 9 Viper Gate System Residential Sliding Gate Operator 6...

Page 7: ...tems tc9sub9 4 10 Base plate for control board Viper Gate Systems tc9bp10 1 11 Chain guard Viper Gate Systems tc9cg11 1 12 Receiver Viper Gate Systems tc9rec12 1 13 Large bracket for magnet open limit...

Page 8: ...call for the use of various tools shown below Other tools may be required as needed for the installation of the concrete pad and electrical connection Table 3 Required Tools for Installation Screwdri...

Page 9: ...ter 6 22 lation Di ter 10 ter 14 er 11 ter 13 RED ter WHITE ter BLUE ter Either wire t Either wire t iagram f 4 3 5 BLACK BLUE RED te YELLOW LIMIT for your V BLUE ter BLACK ter BROWN ter CAPACITOR RE...

Page 10: ...4 Anchors Washers and Nuts in the same bag with the Manual Clutch Release Key Anchors must be set into the concrete at the time of pouring or you can use 5 16 Lead Sink anchors and lag screws not sup...

Page 11: ...two conductor wires with a Ground and protected by a Ground Fault Circuit Interrupt GFCI This can be achieved by using a GFCI receptacle outlet and connecting the Gate Opener to the LOAD terminal of t...

Page 12: ...ounter clock wise to disengage the clutch until it stops use gentle force 4 Install the Chain Box on to the Platform base using the 4 5 8 Socket Head Cap bolts finger tight 5 Install the Angle Iron br...

Page 13: ...re Tie debris 21 Pull as much chain as needed to connect the chain to the Chain Bolt install on the rear of the gate frame and attach to the chain bolt using a Master Link see Figure 1 Note Clutch is...

Page 14: ...actures installation guide for installing and testing a GFCI receptacle 1 Ensure that the electricity to the Outlet Box is OFF 2 Check the Power switch on the Viper Control Board Switch to the OFF pos...

Page 15: ...ssing the remote yellow button will cause the gate to move until the Magnet is positioned over the Limit Senor The gate should now be closed 17 Pressing the Remote Yellow Button again the gate should...

Page 16: ...s 12 long and 10 high At the right side the chain bolt plate was wielded on at the shop as were the two U clamps that attach the extension to the gate left A piece of angle iron was used to support th...

Page 17: ...ly then let go at this Push learn button red light comes on 2 point remote is programmed to your receiver 6 Finally Press the button for the third time you should get a response that means the gate op...

Page 18: ...the corresponding setting from the Gate Operator noted in Table 5 3 Press the Remote Yellow button and verify that the new selected codes operate the gate 4 Replace TC 9 Viper Gate Opener plastic cov...

Page 19: ...TC 9 Viper Gate System Residential Sliding Gate Operator Figure 4 Typical Gate Extension for TC 9 Operator 20...

Page 20: ...TC 9 Viper Gate System Residential Sliding Gate Operator Figure 5 Viper TC 9 Electrical Connection 21...

Page 21: ...TC 9 Viper Gate System Residential Sliding Gate Operator 22...

Page 22: ...Platform 4 Verify that the Safety IR Beam Sensor operates correctly 5 Verify that the Gate Limit Switches are in the correct position for Open and Closed operations 6 Disengage the Clutch using the C...

Page 23: ...witch Security Codes are correct Replace the Remote Battery Gate Opener operates then stops Adjust the Obstruction Sensor and decrease the sensitivity Release the Clutch using the Clutch Key Manually...

Page 24: ...type of gate incorrect weight gate not operating freely or not on level ground The warranty set forth above is entirely exclusive and no other warranty whether written or oral is expressed or implied...

Reviews: