INSTRUCTIONS MANUAL
or Fahrenheit degree.
(T13) Display: According to the operation selected, displays the evacuation time, tank
temperature, or weight of available refrigerant.
STATUS AND ALARM PANEL
See Fig 7:
(C1) REPLACE FILTER: the Low side refrigerant filter/dryer must be changed when the led
“REPLACE FILTER” lights up. When recovering new refrigerant this light may come on
prematurely. It maybe reset bypressing the SEL keywhile turning on the machine.
(C2) HIGH PRESSURE: Lights and emits an acoustic signal when the pressure of the fluid
in the circuit exceeds 290 psi (20 bar). The RECOVERY operation is automatically
interrupted. This will occur if you attempt to recover refrigerant with the tank valves
closed, and will require some disassembly to reset (see TROUBLE SHOOTING
section)
(C3) TANK FULL: Lights and emits an acoustic signal when the bottle is filled to more than
80% of maximum capacity, approximately 40 lbs.
The RECOVERY operation is
automatically interrupted. You may use the CHARGING function to remove refrigerant
from the storage tank.
(C4) LOW REFRIGERANT: Lights and emits an acoustic signal when the quantity of
refrigerant fluid contained in the bottle is low, near 4 lbs (~2 kg). You will need to add
additional refrigerant to continue with a CHARGING function.
C3
C4
C2
C1
Fig.7: Front views
12
Summary of Contents for VR-6000
Page 2: ...INSTRUCTIONS MANUAL ...
Page 9: ...9 ...
Page 14: ...14 ...
Page 15: ...15 ...
Page 23: ...23 ...
Page 32: ...32 ...
Page 37: ...37 ...
Page 38: ...38 ...
Page 46: ...46 ...
Page 56: ...56 ...
Page 61: ...61 ...
Page 62: ...62 ...
Page 70: ...70 ...
Page 74: ...ANUAL DE INSTRUCCIONES 74 ...
Page 75: ...MANUAL DE INSTRUCCIONES 75 ...