3.2.1.2 OPTIONS
ON/OFF TYPE:
There are ignition, timer and ignition or timer three options. They are the modes to boot up the
MDVR device (not for recording). For example, the setting is TIMER from 5:00~12:00am,
MDVR will startup automatically at 5:00am and shut down at 12:00am, but after the MDVR
starts up, it records or not depending on the setting in the SCHEDULE and RECORD
SETTINGS menu.
A)
IGNITION:
for shut down delay function. If the user make the setting for SHOW DOWN DELAY time is
5 min, the MDVR will shut down in 5 minutes after the ignition is off. This means that for example: if the
SHUT DOWN DELAY setting is 1 hour. It is 5:00am when the user turn off the ignition, the MDVR
system will shut down at 6:00am not at 5:00am.
B)
TIMER:
MDVR will boot up or shut down automatically at certain time configured every day.
ViPRO Corporation
User's Manual
MVR-310-GUI | v1.1 | 2014.01
Mobile DVR MVR-310
OPTIONS