background image

 

If you do not connect external storage device or the storage device is defective, the system will display 

NO EXTERNAL STORAGE.   

 

If the MDVR current video type is different with the setting for the MDVR record last time, the video file 

can not playback, for example, the video type of record files is NSTC, but the MDVR recording system 

now is changed to be PAL, you can

t playback the video file until you change the video type to NSTC. 

 

TOTAL: 

total quantity of the files that you selected for back up. 

NO.:

 The file number which is being copied to external thumb drive.   

After successful backup, the following screen will pop up. 

 

       

 

 

 

 

 

 

   

 

     

User's Manual

   

Mobile DVR MVR-500 Series

REC SEARCH

15

MVR-500-GUI | v1.1 | 2014.01

ViPRO Corporation

Summary of Contents for MVR-504

Page 1: ...V FRPSOHWH DQG FRUUHFW DW WKH WLPH RI SULQWLQJ 7KH RQJRLQJ GHYHORSPHQW RI WKH SURGXFWV PD PHDQ WKDW WKH FRQWHQW RI WKH XVHU JXLGH FDQ FKDQJH ZLWKRXW QRWLFH 7KH PDQXDO ZLOO EH NHSW XSGDWLQJ SHULRGLFDOO DQG VRIWZDUH UHIHUUHG DV ZHOO 2014 ViPRO Corporation ...

Page 2: ...ith the release of new version The purpose of this manual is to kindly aid the user for the operation for our MDVR especially for GUI setting The user should have a basic understanding of computer operation and basic knowledge of how to connect peripherals and make some settings Mobile DVR MVR 500 Series NOTICE 2 User s Manual MVR 500 GUI v1 1 2014 01 ViPRO Corporation ...

Page 3: ...STER INFO 20 3 2 1 4 FORMAT 21 3 2 1 5 UPGRADE 22 3 2 1 6 USER SECURITY 23 3 2 1 7 CONFIG 24 3 2 1 8 USER LOG 24 3 2 1 9 GEO FENCING 25 3 2 2 RECORD 26 3 2 2 1 OPTION 26 3 2 2 2 OSD OVERLAY 28 3 2 2 3 CAMERA SETTINGS 30 3 2 2 4 RECORD SETTING 31 3 2 2 5 SUB STREAM 31 3 2 2 6 SCHEDULE 32 3 2 2 7 OTHER SETTINGS 33 3 2 3 NETWORK 34 3 2 3 1 LOCAL 35 3 2 3 2 SERVER NETWORK 35 3 2 3 3 MOBILE NETWORK 36 ...

Page 4: ... 5 TEMPERATURE 43 3 2 4 6 CAMERA 43 3 2 4 7 VOLTAGE 44 3 2 5 PERIPHERAL 45 3 2 5 1 PTZ 45 3 2 5 2 EXT COM SETUP 46 3 3 INFORMATION 46 3 3 1 SYSTEM 46 3 3 2 DIAL STATUS 47 3 3 3 HISTORY 47 3 3 4 MODULES 48 User s Manual Mobile DVR MVR 500 Series Table of Content 4 MVR 500 GUI v1 1 2014 01 ViPRO Corporation ...

Page 5: ...sparent GUI makes setting for GUI and live display synchronously z Mirror recoding makes the hard disk and SD card recording at the same time with same frame same resolution and same image quality z Maximum 1 hour pre recording and 30 minutes post recording z Watermark prevents any modification in recorded file which is part of the law enforcement z Better Compression rate at H 264 50 less than MP...

Page 6: ...Navigation Arrows Use the ARROW keys to move between selections input fields and icons Press ENTER to select And EXIT to return and and entering into the OSD screen to check the MDVR working status Next and previous is also used to increase or decrease volume when at live or search screens User s Manual Mobile DVR MVR 500 Series REMOTE CONTROL 6 recording module and display on screen control menu ...

Page 7: ...tart up when it in sleep mode Switch full screen of one channel to quad view Brightness contrast color adjustment for per channel Use button to change the values You have to adjust the values for each channel individually SETUP Login GUI to setup the parameters EXIT Return to the previous menu STOP Used to stop the recording manually Only valid when you setup the record mode as manual RECORD Used ...

Page 8: ... to USB by press F1 key F2 F3 F4 Reserved for future use 4 PTZ Function Key MXR 500 MDVR can support PTZ camera by the protocol PELCO D or PELCO P While the MDVR is connected the PTZ camera by RS485 signal on the RS232 485 expand box following commands can control PTZ ZOOM IN ZOOM OUT ZOOM IN OUT IRIS IRIS Brightness control FOCUS FOCUS Focus control PTZ Enable the PTZ function AUTO Auto run with ...

Page 9: ...1 3 GUI GRAPHIC USER INTERFACE TREE User s Manual Mobile DVR MVR 500 Series GUI TREE 9 MVR 500 GUI v1 1 2014 01 ViPRO Corporation ...

Page 10: ... the MDVR to a vehicle power supply turn on the vehicle ignition and the unit will automatically start up Power is normally supplied to the MDVR as long as the vehicle ignition is ON Display only view of the cameras is immediately available to be viewed in quad mode Normally the power supply for MDVR is about 12V 3A without any accessories System Login for Setup User s Manual Mobile DVR MVR 500 Se...

Page 11: ...ess LOGIN LOCK OR ENTER key on the handheld controller the setup menu will appear DEVICE NO The unit ID of MDVR You can setup the ID for the MDVR in the menu REGISTER INFORMATION After setting the ID number will appear automatically on the login screen It s the number in the bracket PASSWORD Enter the admin password or user password Keyboard Press ǏEnterǐto use keyboard to type device ID and passw...

Page 12: ...torage medium the recording files are saved into Hard disk is the main recording medium for MVR 500 MDVR but this model can support SD card for mirror recording as well TYPE The type of the file including all file alarm file and normal file DATE MDVR system will display the current date automatically Please select the date you want to search User s Manual Mobile DVR MVR 500 Series SEARCH 12 MVR 50...

Page 13: ...ut not locked YELLOW means the locked alarm files START TIME and END TIME The MDVR device can support the video clip function This time schedule is for both playback locally playback on MDVR device and export export to thumb drive and playback on PC by MINI Player or Ceiba software You have to choose the channel first and then setup the start time and end time for the video clip UNLOCK you have to...

Page 14: ...d time for the video from certain channel for local playback Or you can export the file during certain period to thumb driver or any external storage device and backup to computer for playback exe file This exported exe file can playback easily by MINI player or Ceiba as following By Mini player By Ceiba software Please connect the external storage device with MDVR by USB port and then press Ǐ ǏEX...

Page 15: ...ample the video type of record files is NSTC but the MDVR recording system now is changed to be PAL you can t playback the video file until you change the video type to NSTC TOTAL total quantity of the files that you selected for back up NO The file number which is being copied to external thumb drive After successful backup the following screen will pop up User s Manual Mobile DVR MVR 500 Series ...

Page 16: ...DATE MDVR system will display the current date automatically Please pressǏSEARCHǐto enter into the next menu to list out all the certain video files depends on files type and date SEL For selecting the LOG for backup Please move the arrow key on remote control to select the LOG file that need to back up The file selected will be remarked by the icon Please press ǏREV ǐto for reversing selection Us...

Page 17: ...r example If no there are no any files are selected and you select ǏREV ǐ all the files are selected If one file is selected and select ǏREV ǐthe others will be selected and the originally selected one will be unselected EX LOG Export the selected LOG to external device by USB port on the front of MDVR EXPORT Export the corresponding video if the event has the record file If no related video file ...

Page 18: ...ting the NTP Network Time Protocol the device must have network access connection and assign the NTP IP location TIME ZONE Please choose the correct time zone for MDVR system SYNC TIME This is the time when the unit will sync the system time every day The method depends on the setting on the TIME SYNC SOURCE option NTP SERVER IP Input the IP server does support NTP protocol in order to allow the s...

Page 19: ...UT DOWN TIME The exact time for MDVR shut down every day BOOT UP IN RECORDING TIME ON means timer start up function is linked to record function if you refer to boot up the MDVR and start recording at the same time For example if the record schedule setup is from 6 00 8 00am MDVR will boot up and record automatically if you setup this time on SCHEDULE recording menu during this period even the veh...

Page 20: ...ead from special encrypted chip UNIT ID Device ID Use the NUMERIC keypad on the remote control to enter the system ID from 00000 to 99999 This ID is used to login to the unit if security is enabled set as yes COMPANY NAME The name of company Press the arrow key on the remote control and highlight this option and then input the name of the company VEHICLE NO The number of the vehicles DRIVER ROUTE ...

Page 21: ...MDVR we have hard disk for main recording and SD card for mirror recording If you want to format hard disk please select video storage and if you want to format SD card for mirror please select SD FUNCTION FAST FORMAT SLOW FORMAT and HDD DETECT FAST FORMAT is the same as the fast format on PC SLOW FORMAT means the MDVR system will check whether the hard disk has bad sectors if so the MDVR will mak...

Page 22: ... 3 Please access into the MDVR GUI menu UPGRADE select FIRMWARE option and press ǏUPGRADEǐ MDVR will upgrade the firmware automatically Please make sure you do not remove the thumb drive or cut the power for the MDVR during upgrading the firmware as this is very easily to damage the FLASH for MDVR 4 During the firmware upgrade then following screen will pop up 5 After upgrade success the MDVR syst...

Page 23: ... technical support trying to upgrade the firmware by TFTP upgrade MCU UPGRADE The step is the same as upgrade firmware 3 2 1 6 USER SECURITY Setup the password for user and admin PASSWORD ENABLE To active password access Selecting ON will require a password in order to access the setup menu USER PASSWORD User authority can only check the image from each camera can t modify any parameters ADMIN PAS...

Page 24: ...ll backup to external device RESET Reset all the history info to default values IMPORT Follows the operation EXPORT Import the MDVR configuration file to the MDVR except MAC address and IP Please insert the external storage device to the USB port on the MDVR Must have configuration file in the storage device and then press ǏIMPORTǐ The configuration will import to another MDVR automatically RESTOR...

Page 25: ...nd it will be save to userlog 00000 0 folder according to date 3 2 1 9 GEO FENCING GEO FENCING SWITCH this is the switch to enable GEO Fencing function This switch is only for MDVR User s Manual GEO FENCING 25 Mobile DVR MVR 500 Series MVR 500 GUI v1 1 2014 01 ViPRO Corporation ...

Page 26: ...o export to another MDVR Remark Geo fencing means you can setup a special virtual area for the vehicle when the vehicle enters into or out of this area the MDVR system will trigger the alarm For more details please check the CMS manual 3 2 2 RECORD Setup the related configuration for record 3 2 2 1 OPTION The menu is used to setup the basic parameters for MDVR recording VIDEO TYPE PAL and NTSC opt...

Page 27: ...f the setting for alarm duration is 10 sec and during this 10 sec anther same type like panic button alarm triggered MDVR system will consider them to be one alarm event And the alarm start time will be reset based on the second time for alarm ALARM POST REC 30 1800 SEC Alarm post recording time BUZZER TIME buzzer alarm duration time setup when alarm is triggered MEDADATA CAPTURE metadata informat...

Page 28: ...files you can lock or unlock them Lock function is only for the event alarm files as they are very important The locked files cannot be deleted by the HDD SD overwrite function in the retention days When the retention day is expired the locked files will be unlocked automatically and deleted Locked recording file save time can be configured to be 7 10 15 20 30 45 days During the retention time the...

Page 29: ...CLE NO Display the vehicle NO SPEED Display the speed on OSD RECORD is ON means it will record the date time channel name and vehicle NO into the record files To get the main information for MDVR working easier on QUAD view you can please just press ǏEnterǐ on remote control to show below screen This screen will show all the important working information for the MDVR including sensor 3G GPS WIFI s...

Page 30: ... view ROUND Means channel loop function sequence if you setup time as 5 second which means the video screen will shift to different channels the sequence is from channel 1 to channel 4 in every 5 seconds IP INTERCOM This is the switch for intercom function we also say 2 way audio which means that that driver can talk with server directly via wireless network 3G When this switch is ON the audio of ...

Page 31: ...cond 1 25 or 1 30 for NTSC can be adjustable QUANLITY Image quality 8 levels optional Level 1 is the best Normal quality is the quality for normal record and alarm quality is for alarm record 3 2 2 5 SUB STREAM Sub stream is the settings for 3G wireless transmission you can setup the bandwidth and enable the channels Otherwise it can t transmit the live video to PC software center server The setup...

Page 32: ...change the type of the recording mode Con Continuous recording Alarm Alarm recording Timer timing recording Schedule 1 2 Press the RIGHT ARROW key to enter values using the NUMERIC keypad into any time field Schedule 1 is the first of two possible ON OFF cycles that apply to any day in the period chosen under Date Schedule 2 is the second cycle for any day in the period There is no need to overlap...

Page 33: ...for the regular monitor output display CP3 is the Control Panel which can support one LED to display the image and realize the station annoucement functon the precondition is the MDVR device can support the station annoucement function either Quad Image Interface CP3 Interface User s Manual OTHER SETTINGS 33 Mobile DVR MVR 500 Series MVR 500 GUI v1 1 2014 01 ViPRO Corporation ...

Page 34: ...or the audio announcer 3 2 3 NETWORK This part will explain how to setup the network function RJ45 cable connection WIFI connection 3G for MDVR First we need to know the PC software that the MDVR supports for MVR 500 MDVR CMS Ceiba ADS CMS Central Management Software is the software to manage the vehicles real time via 3G Ceiba is the playback and analysis software ADS is the downloading software ...

Page 35: ... at present WEB PORT this port is for IE access you have to add this port when you want to access to MDVR through IE browser of example you have to access MDVR by http 192 168 3 155 10090 DNS The DNS of the router when you want connect MDVR to internet via cable please setup the DNS here MAC Address MAC address is uniquely and cannot change it 3 2 3 2 SERVER NETWORK The sever IP and port setting f...

Page 36: ...ce is to setup the wireless modules type active mode and SIM card parameters when you connect with net cable please select mode type as NONE ACTIVE MODE There are three options ALWAYS means when MDVR started up the wireless module will always dial up and connect to message server CALL SMS means only you call the phone number of the SIM card or send the message to the SIM it will active the wireles...

Page 37: ...lease check the setup as follow form INTERCOM SETTINGS it s a switch for interphone function which can realize speak to center via SIM card User s Manual MOBILE NETWORK Mobile DVR MVR 500 Series 37 MVR 500 GUI v1 1 2014 01 ViPRO Corporation ...

Page 38: ...the server limit If the local IP of MDVR is 192 168 3 233 you can log in the MDVR FTP server as follow ftp 192 168 3 233 and the recorded file save path is ftp 192 168 3 233 stm disk 0 p1 2012 11 23 The default login username is admin password is 88888888 if you can t login at the first time please try again User s Manual FTP SETTINGS 38 Mobile DVR MVR 500 Series MVR 500 GUI v1 1 2014 01 ViPRO Cor...

Page 39: ...rd Enter the text name to identify the source of each sensor connected to the unit OSD Input the numbers and characters they will be embedded into the alarm video files when alarms happen and it will also display in live view Please pressǏEnterǐ into the soft keyboard The label also identifies the type of event when doing a quick search using EVENT SEARCH option SET LOW normal close means the powe...

Page 40: ...ans setup the alarm linkage for each sensor for example you setup the image of channel 1 as the alarm linkage for sensor1 when the alarm from sensor1 is triggered the image from channel 1 will change to be full screen And the priority is from sensor 1 to sensor 8 Sensor1 priority is highest Sensor 8 priority is lowest 3G ACT means you can define a sensor to active the 3G module as there is an acti...

Page 41: ...input can trigger this output OFF means can t 3 2 4 3 SPEED Setup the alarm for over speed and some other parameters User s Manual SENSOR OUTPUT 41 Mobile DVR MVR 500 Series MVR 500 GUI v1 1 2014 01 ViPRO Corporation ...

Page 42: ...r dash board and keep this speed at 30 seconds then press the Check to make the system calibrate the second area HZ set as first area data 80 SPEED UNIT MPH or KPH MILEAGE is the total mileage that the MDVR has run OVER SPEED If the vehicle exceeds the high speed limit MDVR will trigger the alarm signal when the following option ALARM set as YES until the driver slows down the speed LOW SPEED If t...

Page 43: ... working temperature is higher than the setting for HIGH TEMP MDVR will trigger alarm If the MDVR working temperature is lower than the setting for LOW TEMP MDVR trigger will alarm 3 2 4 6 CAMERA Display the alarm information from camera User s Manual ACCELERATION 43 Mobile DVR MVR 500 Series MVR 500 GUI v1 1 2014 01 ViPRO Corporation ...

Page 44: ...itive M D AREA this option is for user to setup the detect area as follow blank square means the area is selected please exits to the setup interface to save the settings 3 2 4 7 VOLTAGE VOLTAGE PROTECTION means when MDVR system detects that the voltage input always in a low status MDVR will disconnect to CMS and shutdown automatically User s Manual CAMERA 44 Mobile DVR MVR 500 Series MVR 500 GUI ...

Page 45: ...wn automatically 3 2 5 PERIPHERAL 3 2 5 1 PTZ CHANNEL The channel of PTZ connected PROTOCOL select the protocol of different PTZ there are two protocols to switch and the default is Pelco D BAUD RATE select the different baud rate for your PTZ there are 1200 2400 4800 and 9600 DATA BIT there are 5 6 7 8 options to select default setting is 8 STOP BIT there are 1and 2 to select the default setting ...

Page 46: ...fier board they are unchangeable COM3 and COM4 is changeable And 485BUS is switch for smart battery connection 3 3 INFORMATION 3 3 1 SYSTEM Display the MCU version firmware version HDD status and SD card information 1 NO HDD means No HDD installed or the HDD is defective and cannot work 2 NO FORMAT means HDD installed but not formatted All the new hard disk must be formatted after installation 3 s...

Page 47: ...s that how long that the hard disk can recording based on the current configuration of the MDVR like image quality resolution frame rate with the free space 3 3 2 DIAL STATUS The data for dial status information 3 3 3 HISTORY The data for history information User s Manual DIAL STATUS 47 Mobile DVR MVR 500 Series MVR 500 GUI v1 1 2014 01 ViPRO Corporation ...

Page 48: ...Press ǏCLEARǐto delete all the current data 3 3 4 MODULES Display the GPS module information User s Manual HISTORY 48 Mobile DVR MVR 500 Series MVR 500 GUI v1 1 2014 01 ViPRO Corporation ...

Page 49: ...User s Manual MODULES 49 Mobile DVR MVR 500 Series MVR 500 GUI v1 1 2014 01 ViPRO Corporation ...

Reviews: