Maintenance

3

Section 2

Maintenance

2.1 Replacing UV Lamp

Lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000 
hours of continuous operation (approximately one year) in order to ensure adequate disinfection.

Procedure:

WA R N I N G

  •

Always disconnect power before performing any work on the disinfection system.

  •

Always shut-off water flow and release water pressure before servicing.

  •

Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present.

  •

Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum disinfection.

  •

Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures.

N O T I C E

Do not use water during replacement of UV lamp.

1

•   

Shut off the water line to 
chamber and release system 
pressure before servicing.

•   

Close all faucets.

22

0

30

15

45

10 mins

•   

Disconnect main power 
source and allow the unit to 
cool for 10 minutes.

3

1

2

•   

Disconnect the lamp 
connector and UV lamp from 
the retaining nut. 

4

•   

Rotate the retaining clip 
locking tabs to unlock the 
lamp connector.

•   

Pull the lamp connector along 

with the UV lamp from the 
retaining nut. 

5

•   

Disconnect the lamp 
connector from the UV lamp.

6

Hg

UV

•   

Remove the UV lamp without 

twisting and discard the lamp.

Note: 

Always hold the UV 

lamp at the ceramic ends.

55

Hg

UV

Hg

UV

57

Hg

UV

Hg

UV

•   

Insert the new lamp fully into 
the sleeve leaving about two 
inches of the lamp protruding 
from the chamber.

8

•   

Connect the lamp connector 
to the UV lamp.

Summary of Contents for Hi-Flo

Page 1: ...could result in serious personal injury or damage to the equipment Make sure that the protection provided by this equipment is not impaired Do not use or install this equipment in any manner other tha...

Page 2: ...rate injury Thermal Hazard Allow UV lamps UV chamber to cool for a minimum of 10 ten minutes before handling When there is no water flow the water in the chamber will become hot To prevent scalding al...

Page 3: ...seasonal home or leaving the unit in an area subject to freezing temperatures NOTICE Do not use water during replacement of UV lamp 1 Shut off the water line to chamber and release system pressure be...

Page 4: ...e connector is fully seated onto the UV lamp 9 1 2 Slide the lamp connector up to the retaining nut Rotate the retaining nut locking tabs to lock the lamp connector in place Connect the ground cable a...

Page 5: ...f the system is put on a temporary by pass or if it becomes contaminated after the disinfection system it is necessary to shock the system with household bleach for a full 20 minutes before resuming t...

Page 6: ...2 2 Note The quartz sleeve and UV sensor should be cleaned at the same time Procedure WA RN IN G The UV sensor is very delicate instrument Extreme care is required when handling and cleaning The senso...

Page 7: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com...

Reviews: