Monitored Systems incorporating BA-ICE-M-HF controller:
1. UV intensity (%):
The Hi-Flo Monitored series of products incorporate a UV sensor which detects the
discrete 254 nm wavelength of the UV lamps. This information is relayed to the top
Hi-Flo Monitored controller and is the default display shown in “% UV output”. The
system will display the UV output between 50 to 99 percent. When the system drops
below 50%, a low UV warning is displayed as and alternately flashes (at 2
second intervals) back to the actual UV level. Eg. Additionally, the system
will supply an intermittent audible tone (2 seconds on, 2 seconds off), during low UV
conditions.
Note:
UV levels of ...
to
Indicates the system is functioning within a normal
operating range.
to
Indicates the UV level is still within a safe level, however cleaning
or lamp replacement may soon be required.
to
Indicates the UV level is nearing the point of unsafe UV intensity,
UV system should be immediately serviced.
Indicates the UV level has now reached a level that is unsafe. At
this level the water should not be consumed. The system/water
supply should be examined to determine the reason for the low
UV level of the UV intensity. At this level, the solenoid output has
been activated and if a solenoid is installed, water will cease to
flow.
DEFERRAL
- To temporarily defer the audible alarm and re-activate solenoid valve (if
fitted) during a low UV alarm, press the push-button “RESET” switch and hold for five
seconds. This will mute the audible alarm condition and activate solenoid output for
12 hours.
This advanced warning system has been installed to provide
you with the optimum protection against microbiological
contamination in your water.
DO NOT DISREGARD THE WARNING SIGNALS.
The best way to ensure optimum UV performance is to have
the water microbiologically tested by a recognized testing
agency on a regular basis.