42
Put the jaw holding plate down, rear facing upwards, and unscrew the jaw holder helical drive
ring:
Turn the jaw holding plate over and remove the three jaw holders:
Put the new jaw holders into their correct numbered locations: jaw holder no. 1 in slot no.1,
jaw holder no. 2 in slot no.2 and jaw holder no. 3 in slot no.3.
Turn the plate with its three jaw holders over. Position the start of the drive ring spiral opposite
jaw holder no.1 and insert the jaw holder into the spiral. Turn the ring 120° such that the start
of the spiral is opposite jaw holder no.2 and insert the jaw holder. Do the same for jaw holder
no.3. Continue to turn the ring until the jaw holders are completely blocked.
If necessary, replace the chuck crown around the spindle nose and place the jaw holding
plate on the spindle nose, lining up the nose pin with the slot on the disc (see figures on the
next page).
●
●
●
●
●
EN
Summary of Contents for 162120
Page 1: ...Threading machine for tubes up to 2 Instruction Manual 162120 EN ...
Page 3: ...EN ...
Page 51: ...49 Exploded view of the motor and the oil pump Pump EN ...
Page 52: ...50 Exploded view of the transmission EN ...
Page 53: ...51 Exploded view of the saddle EN ...
Page 54: ...52 Exploded view of the automatic opening 2 die head EN ...
Page 55: ...53 Exploded view of the 1 4 3 8 die head EN ...
Page 56: ...54 Exploded view of the tube cutter EN ...
Page 58: ...56 Components of a nipple holder EN ...
Page 59: ...EN ...