background image

 

 
Elbilgrossisten AS 
Stockholmgata 20 
0566, Oslo 

 

 

Postal address: 
Elbilgrossisten AS 
Postboks 6679 Rodeløkka 
0502, Oslo 
 

Contact information: 
Tel: +47 23 90 55 15 
Mail: 

kundeservice@elbilgrossisten.no

 

 

Page 3 of 10

 

1.0 

Technical information about Viridian EcoLite charging station 

Viridian EcoLite charging station is developed to supply power to electric vehicle. The charging 
station  comes  with  a  residual  current  device  Type  B  to  protect  against  direct  current  (DC) 
leakage (pulsating and smooth DC) which may occur after the cars rectifier and might leak 
back onto the power line.  

 

1.1Type 2 socket 

 
Number of conductors: 1 / 3+ N 
Number ampere: 6 

 32A 

Maximum output: 22kW 

 

1.2 Technical specifications 
 

The charging station is manufactured in powder coated steel housing that provides high finish, 
quality and durability. Built-in LED light in the front plate indicating the charging process - red, 
green and blue. 

IP classification: IP54 - suitable for outdoor use. 

 

1.3 Operating 
 

Cleaning: No specific cleaning requirements and avoid use of water for washing. 
Energy consumption: 2W standby 
Maintenance: Check for mechanical and external damage regularly 
Longevity: Depending on the environment - minimum 2 years. 

 

1.4 Dimensions 
 

Height: 32cm 
Width: 23cm 
Depth: 13cm 

 

 

Summary of Contents for EcoLite

Page 1: ...0566 Oslo Postal address Elbilgrossisten AS Postboks 6679 Rodeløkka 0502 Oslo Kontaktinformasjon Tel 47 23 90 55 15 Mail kundeservice elbilgrossisten no Side 1 av 10 Installation and user manual for Viridian EcoLite 3 7kW til 22kW English ...

Page 2: ...ITE CHARGING STATION 3 1 1TYPE 2 SOCKET 3 1 2 TECHNICAL SPECIFICATIONS 3 1 3 OPERATING 3 1 4 DIMENSIONS 3 2 0 INSTALLATION OF VIRIDIAN ECOLITE CHARGING STATION 4 2 1 CONNECTION 4 2 2 MOUNTING OF CHARGING STATION 5 3 0 ADJUSTING THE AMPERAGE NUMBER OF AMPS 7 4 0 TEST OF CHARGING STATION AFTER INSTALLATION 7 4 1 LED SIGNAL CODES 7 5 0 SAFETY MECHANISMS 8 5 1 TYPE 2 CONNECTOR OUTLET 8 5 2 LOCKING THE...

Page 3: ...e cars rectifier and might leak back onto the power line 1 1Type 2 socket Number of conductors 1 3 N Number ampere 6 32A Maximum output 22kW 1 2 Technical specifications The charging station is manufactured in powder coated steel housing that provides high finish quality and durability Built in LED light in the front plate indicating the charging process red green and blue IP classification IP54 s...

Page 4: ...ing station supports all power grids 230V 1 3 phase IT og 400V 3 phase TN and can be connected as 1 1P N 1 phase 400V TN S a L1 and N are connected and the charging station is connected as 1 phase 230V 2 2P 1 phase 230V IT a L1 and N are connected and the charging station is connected as 1 phase 230V 3 3P 3 phase 230V IT a L1 L2 and N are connected and the charging station is connected as 3 phase ...

Page 5: ...AS Stockholmgata 20 0566 Oslo Postal address Elbilgrossisten AS Postboks 6679 Rodeløkka 0502 Oslo Kontaktinformasjon Tel 47 23 90 55 15 Mail kundeservice elbilgrossisten no Side 5 av 10 2 2 Mounting of charging station ...

Page 6: ...Elbilgrossisten AS Stockholmgata 20 0566 Oslo Postal address Elbilgrossisten AS Postboks 6679 Rodeløkka 0502 Oslo Contact information Tel 47 23 90 55 15 Mail kundeservice elbilgrossisten no Page 6 of 10 ...

Page 7: ... NB Turn of the RCD type B switch before performing this as these are powered contacts The table shows the various resistors that must be used to adjust the current Resistance Ω Ohm Amperage Number of amps 249 10A 348 16A 432 20A Unattached resistance 32A 4 0 Test of charging station after installation To test the charging station connect a suitable mode 3 charging cable to the Type 2 connector an...

Page 8: ...harger connector on the charging station and the vehicle This is to prevent accidental disruption of the charging and prevent the theft of the charging cable The charging cable is is locked in place with a 12V solenoid and the charging station releases the plug if it loses power supply or if a fuse blows This is why there is a vacuum hose in the bottom of the charging station 5 2 Locking the charg...

Page 9: ... charging Error message 2 The charging process is interrupted during charging 1 Check the earth fault protection RCD and circuit breaker a The RCD might have been triggered due to security reasons 2 Check if the car signals an error message e g charging not possible a In some rare cases electric vehicles may interrupt the charging process due to discrepancies by the power supply Contact an electri...

Page 10: ...ions Phone 47 23 90 55 15 E mail kundeservice elbilgrossisten no Facebook https www facebook com Elbilgrossisten Warranty Your Viridian charging station comes with three 3 years factory warranty Contact us as soon as possible if you were to receive a defective damaged product or if an electrician is unable to install the charging station due to a malfunction of the product We ask that you take pic...

Reviews: