eco-CONTROL EC200-B
Operation and maintenance instructions
If the
Level monitoring
function has been activated with
ON
, the
Ext. level sensor
switch
can be used to switch between the signal input at the
plug
sensor
(17) =
OFF
and
system plug (19) =
ON
.
The volume is set with the
NAVI wheel
and confirmed with the
Enter
key.
All the values that are set here are saved permanently in the Dosing system.
Note:
The overcurrent monitoring is set permanently to ON.
The primary pressure and level monitoring functions protect the dispenser. This
effectively prevents any damage due to running dry if there is too little medium.
(Connection for the level signal, see 5.2, Connections, page 11)
Error message SD chipcard
If the chipcard is defective or has not been inserted, when
the Dosing systems is switched on a corresponding
message (display 37) is shown for 3 seconds.
D
is
pl
ay
3
7
5.11
Clearing error messages
If there is an error message, it is shown flashing in the
status line (display 36) and an acoustic signal is given
(if it has not been switched off, see 5.10.10, System and
error messages, page 26)
• Press the
Info
key, the acoustic signal is switched off, and
the corresponding error message appears.
D
is
pl
ay
3
6
• Correct the error and clear the error message with
OK
.
Caution:
If the error message
Overcurrent switching
appears, the dispenser must be
cleaned before any further use.
Can´t find memory card.
10 47h
Fr 18.03.11
Fault
Esc
Suckback
Flow rate
Volume
0%
100%
ml/min
00.100
03.000
00.000
ml
ml
Alarm messages
Quit
OK
Over current shutdown!
Read manual!
Check dispenser!
Alarm messages
Quit
Check pressure!
OK
Desired pr.
Actual pr.
1.0Bar
0.2Bar
Alarm messages
Quit
Level minimum
OK
Check level!