4.5
Organizational measures
The owner is to provide any personal protective equipment
that is required. All the safety devices are to be checked
regularly. Wear protective glasses and a protective suit for
operation and cleaning to protect against any chemicals
that are sprayed out.
All the safety information in the relevant Operation and
maintenance instructions of the dispenser(s) connected to the Dosing system must be
complied with.
4.6
Preparation before starting up - visual check
Make a visual check of the Dosing system daily, before starting work, and before each
shift change. If there is any doubt at at that the unit is not perfectly ready for operation, it
must be shut down at once and inspected by a suitably qualified person before it used
again.
4.7
Preventing damage to the motor of the dispenser
Only remove and insert the mains plug of a dispenser (plug 16, section 5.2,
Connections on page 11)
when the power has been switched off
. Otherwise
the electronics of the drive motor could be damaged.
4.8
Sources of danger due to Dosing system
» Very high dosing pressures can be produced, depending on the viscosity and the speed
of rotation, and this could result in unintended spurting out of the medium.
Check the
flow quantity in relation to the dosing needle used (needle cross-section).
» When it is started up for the first time and after being refilled, air bubbles that are
included in the medium could cause an uncontrollable spurting out of the outlet nozzle.
Only start production operation once the Dosing system has been completely
bled.
» Wear suitable protective clothing if chemical, corrosive or dangerous products are being
used.
Note and comply with the safety stipulations and the information from the
manufacturer.
Ensure sufficient bleeding or extraction of air. Take special safety
precautions if working with dangerous media, for example, provide eye flushing
facilities if working with corrosive chemicals.
Failure to follow the instructions given below can result in damage to the unit and
possible severe injury to persons in the vicinity.