13 / 32
eco-PEN600
4.1.1
Fitting the stator
Coat the rotor (4) with material or a suitable lubricant.
Turn the stator (7) in the correct position (see detailed view) on the rotor (4) until the dowel
pin (8) begins to dip into the keyway (9).
Lightly press the stator (7) towards the pump housing (19) and turn the assembly aid (6) in
the direction of the arrow until the stator (7) has been guided into the pump housing (19).
Uncouple the assembly aid (6), install the end piece (3) and the cap nut (2), and put in place
the required Luer-Lock needle.
4.1.2
Connecting the dosing unit to the drive unit
Screw the set screws (14) into the thread so that they do not protrude into the coupling area.
Danger of damage to the fit.
Attach the star-shaped coupling (5) onto the coupling of the drive unit (11).
Set the anti-rotation lock (8) in the correct position relative to the dosing unit (20).
Fully assemble the dosing unit (20) and the dosing unit (11).
Lightly turn the set screws (14), the drive unit (11) has now been centred properly.
2
3
4
9
7
19
5
6
13
X
8
7
11
Fig. 2
8
11
5
14
14
20
Fig. 3