21
Rear Connections
Various connectors are used on the back of the
TruckWeigh™ meter. These are shown opposite:
Power Connection
Locate a suitable point to connect to the truck’s 12V power
supply. The meter would normally be powered from a power
source that is on when the trucks ignition key is turned to the
first position.
The power supplied to the meter must be protected by a
3A fuse.
Brown
3A Fuse
+12V
0V
Black
White
Brown
Blue
Blue
Positive
Positive
Negative
Negative
Rear view of optional alarm
+
+
-
-
-
-
Note:
The blue and white wires will be required if you are
connecting the optional alarm, see below. If they are not
used to feed an external alarm they must be terminated in
such a way as to insulate them.
Install External Alarm (Optional)
Fit the alarm in a location that provides some protection from
dirt and rain but allows the alarm to be heard.
The alarm connects to the meter power cable as shown in
figure 1.65.
Fig 1.62
Fig 1.65
Fig 1.63
Fig 1.64
Installation
SI Onboard TruckWeigh™ Manual