54
Default Value
Outputs
Serial output -
Printer
Baud rate
The data speed for the printer. It can be set to 1200, 2400,
9600, 19200, 57600 bits per second
9600
Handshake
This is a signal that tells the meter to stop sending data until
it has space in its buffer for more
Off
Print header
The header is user configurable, this option turns it on or off
On
Change print
header
Edit the print header by scrolling through the words,
changing the letters using the up and down buttons
Serial output -
Scoreboard
Baud rate
The scoreboard output is a continuous stream of weight
data. The data speed for the printer. It can be set to 1200,
2400, 9600, 19200, 57600 bits per second.
9600 Note 2
Handshake
This is a signal that tells the meter to stop sending data until
it has space in its buffer for more
Frequency
The time between data packet sets. This can be set to 0.5s,
1s, 2s,5s,10s
5 seconds
Acknowledge
required
This is where the device receiving the data acknowledges
each bit of data before the meter sends the next one. It
allows for data to be re-sent.
No
Transmit retries
This is the number of times the data above is re-sent. It can
be set to 1,2,3,4,5 or 6 times.
2
Barrier control
Barrier
This feature is intended for load cell systems. It is used to
request the barrier of a garbage truck moves forward when
the rear axle weight(s) are close to maximum.
Off
Barrier control
Barrier
This feature is intended for load cell systems. It is used to
request the barrier of a garbage truck moves forward when
the rear axle weight(s) are close to maximum.
Off
Maximum
incline
The operation of the barrier control feature is inhibited if the
trucks pitch angle exceeds this
3.0⁰
Front axle(s)
under load
If this feature is enabled and the front axle(s) weight(s) are
less than 20% of trucks current GVW it will request the
barrier to move forward
Off
Axle 1 overload Axle 1 overload is not currently used for anything
20900 lbs
Axle 2 overload
If the truck has 2 or 3 axles and this figure is exceeded for
longer than the filter time on level ground the move barrier
forward signal is asserted
20900 lbs
Axle 3 overload
If the truck has 3 or 4 axles and this figure is exceeded for
longer than the filter time on level ground the move barrier
forward signal is asserted
20900 lbs
Axle 4 overload
If the truck has 4 axles and this figure is exceeded for longer
than the filter time on level ground the move barrier forward
signal is asserted
20900 lbs
Filter weight
The weights from the axles triggering the barrier control
need to be stable within this figure for the time below before
the move barrier forward signal is asserted
200 lbs
Filter time
See above
4 seconds
SI Onboard TruckWeigh™ Manual
Appendix B
Summary of Contents for VPG On-Board Weighing SI Onboard TruckWeigh
Page 5: ...5 Installation SI Onboard Installation SI Onboard TruckWeigh Manual Installation ...
Page 23: ...23 Setup Setup SI Onboard TruckWeigh Manual ...
Page 36: ...36 Installation SI Onboard SI Onboard TruckWeigh Manual Setup ...
Page 37: ...37 Calibration Calibration SI Onboard TruckWeigh Manual ...
Page 42: ...42 SI Onboard TruckWeigh Manual Calibration ...
Page 43: ...Appendices Appendices SI Onboard TruckWeigh Manual ...
Page 58: ...58 SI Onboard TruckWeigh Manual Notes ...
Page 59: ......