55
Default Value
CAN output
This is a data output for some VPM supplied add on options
such as 511 hand held remote display
No
Remote channel
You can choose the radio channel for a 511 hand held
remote display, from channel A to O.
A
Aux output 1
This output can operate 12V out of the expansion
port on the rear panel of the meter when there is an alarm
condition.
Off
Aux output 2
This output can operate 12V out of the expansion
port on the rear panel of the meter to request a garbage
truck requests its barrier to move forward.
Off
Set time/date
Set the time and date and enable daylight saving.
PIN access
Set manager PIN
The manager PIN secures the setup menus from
unauthorized tampering. The PIN can be set to whatever the
customer wants
7711
Set user PIN
The user PIN can only be enabled in addition to the manager
PIN. It secures the alarm setting menus from unauthorized
tampering. The PIN can be set to whatever the customer
wants
0000
PIN control
You can select from PIN – Off, PIN Manager and
PIN User/Manager
Manager
Reset
Re-learn
This option makes the meter “forget” extra devices it has
previously had connected that are no longer connected.
Reset defaults
This re-loads the meters factory default values for all the
items that can be set/configured.
Diagnostics
System
Shows battery and transducer excitation voltages and the
firmware version
JBox config
Shows what the junction boxes are and what transducer
numbers they are configured to be able to address
JBox software
version
Shows the firmware versions in the attached junction boxes
External inputs
Shows the status of the external switch including axle down
signal on input 1
Adjusted net
There are the net weights each sensor is actually measuring
Raw net
This figure is calculated from defined parameters and may
be of use to a SI Onboard engineer
Signal
Axle Transducers - represents the sensor angle and will have
2 decimal places (Horizontal = 90.00°)
Air Transducers – represents the actual voltage from the air
pressure transducer and will have 1 decimal place. Typically
from 0.5V to 4.5V.
These can be used to assist in diagnosing problems.
Appendix B
SI Onboard TruckWeigh™ Manual
Summary of Contents for VPG On-Board Weighing SI Onboard TruckWeigh
Page 5: ...5 Installation SI Onboard Installation SI Onboard TruckWeigh Manual Installation ...
Page 23: ...23 Setup Setup SI Onboard TruckWeigh Manual ...
Page 36: ...36 Installation SI Onboard SI Onboard TruckWeigh Manual Setup ...
Page 37: ...37 Calibration Calibration SI Onboard TruckWeigh Manual ...
Page 42: ...42 SI Onboard TruckWeigh Manual Calibration ...
Page 43: ...Appendices Appendices SI Onboard TruckWeigh Manual ...
Page 58: ...58 SI Onboard TruckWeigh Manual Notes ...
Page 59: ......