G4 Multi Channel Weighing Instrument
6-21
Scale X: Gross weight
This register holds the gross weight for a scale. The weight should
not
be read alone
because the status and error codes are stored in other registers. The weight is only
valid when the register ‘Scale X:Error code’ equals 00.
Scale X: Net weight
This register holds the net weight for a scale. The weight should
not
be read alone
because the status and error codes are stored in other registers. The weight is only
valid when the register ‘Scale X:Error code’ equals 00.
Scale X: Flow rate
This register holds the flow rate for a scale. The flow rate should
not
be read alone
because the status and error codes are stored in other registers. The flow rate is
only valid when the register ‘Scale X:Error code’ equals 00.
Scale X: Input signal (mV/V)
This register holds the current input signal in mV/V for a scale. This register could be
used for fault finding in the system.
Analog output value 1, 2, 3, 4
These registers holds the values sent to the analog outputs. The registers can be used
for fault finding in the system.
Note:
The value is rounded to 3 decimals.
Status of inputs 11-18, 21-28
Bits set to 1 in this register have the following meaning:
Bit no Function
Bit no Function
0
Digital input 11 activated.
8
Digital input 21 activated.
1
Digital input 12 activated.
9
Digital input 22 activated.
2
Digital input 13 activated.
10
Digital input 23 activated.
3
Digital input 14 activated.
11
Digital input 24 activated.
4
Digital input 15 activated.
12
Digital input 25 activated.
5
Digital input 16 activated.
13
Digital input 26 activated.
6
Digital input 17 activated.
14
Digital input 27 activated.
7
Digital input 18 activated.
15
Digital input 28 activated.
Note: If this register (bits) is read as float value,
see description of Data representation.
Status of inputs 31-38, 41-48
Bits set to 1 in this register have the following meaning:
Bit no Function
Bit no Function
Summary of Contents for G4
Page 2: ......
Page 18: ...Technical Manual 1 14 ...
Page 39: ...G4 Multi Channel Weighing Instrument 3 7 ...
Page 104: ...Technical Manual 5 18 ...
Page 158: ...Technical Manual 6 54 ...
Page 178: ...Technical Manual 7 20 ...
Page 186: ...Technical Manual 8 8 ...
Page 196: ......
Page 197: ...G4 Multi Channel Weighing Instrument Appendix 1 ...
Page 198: ...Technical Manual ...
Page 199: ......