G4 Multi Channel Weighing Instrument
2-5
VIEWPAN module
The output of the external dc supply must be rated 24 V
, ±15% including
fluctuations, min. 40 W. The supply must provide Double Insulation between
Mains parts and 24 V SELV or SELV-E Circuit, and a limited-energy circuit
(maximum available current of 8 A).
For the US market this energy limit can be achieved with an
ANSI/UL248-14 fuse rated 5A.
For other markets an IEC 60127 T type fuse rated 4A may also be used.
With integrated 24 V
power supply unit.
The integrated power supply is used to supply the complete instrument.
24 V
input
Terminals 1, 2 and 3.
The G4 instrument should be powered by 24 V
,
connected according to the diagram below.
To achieve functional grounding, terminal 3
should be connected to ground.
See Technical data for input voltage ratings.
24 V
output
Terminals 4 and 5 can be used to supply
max. 100 mA to digital inputs and outputs.
Connection should be according to
the diagram below.
See Technical data for ratings.
1
DC SUPPLY
2
0 V
3
Shield
4
5
0 V
6
Shield
0 V
Ground
0 V
+24 V In
+24 VDC In
+24 VDC Out
+24 V Out
!
Summary of Contents for G4