G4 Multi Channel Weighing Instrument
5-9
command is given either from front panel or via communication. Note that the displayed
weight is accumulated.
In the Accumulated Weights menu there is a possibility to zero all values by using the
‘Zero ALL values?’ function or to zero (or edit) one value at a time.
The instrument is capable of storing accumulated weight values up to 10 000 000 000
units with 3 decimals. When the limit is passed 10 000 000 000 will be subtracted from
the value.
Batched Weights:
Batched Weights are accumulated weights that are automatically
calculated when batching. There is one sub menu for each used scale. In each sub
menu there is one accumulated value for each used activity (of batching type) and one
total i.e. one sum of all activity accumulations. See separate description for ‘Scale
Batching Program Option’ ‘Technical Manual Supplement’. Note that this menu is only
shown if the Scale Batching Program Option is enabled.
In the Batched Weights menu there is a possibility to zero all values, for a scale, by
using the ‘Zero ALL values?’ function or to zero (or edit) one value at a time.
The instrument is capable of storing batched weight values up to 10 000 000 000 units
with 3 decimals. When the limit is passed 10 000 000 000 will be subtracted from the
value.
Clock Set-up:
Used to set the instrument clock and date. Time and Date formats are
set-up with parameters trough ‘Param. Set-up’ menu.
Param. Set-up:
Access to the G4 instrument parameter set-up menu system.
See chapter ‘Set-up’ for more details on setup.
System Info:
Displaying system information for hardware and software in
the instrument. Program versions, database version, serial numbers and
software versions for all electronic modules can be read here.
Info about the Ethernet connection is also available.
Maintenance:
Includes a number of functions for maintenance purposes. The available
functions are Diagnostics, File Handling, Create Backup, Restore Backup, Set Default
Values and Program Upgrade.
See chapter ‘Maintenance’ for a detailed description of the functions.
Network Configuration:
The Network Configuration menu consists of the IP Config.
and the Server Config. menus. The IP Config. menu is used to set, manual/auto IP
address assignment, IP address etc. The Server Config. menu is used to
enable/disable the FTP Server and the WEB Server of the instrument. In this menu is
also the password for the servers set.
Note that Ethernet configuration is not done with set-up parameters and is for that
reason not saved with the instrument back-up function.
To return to the Weight display press the ‘
↑
’ key.
Summary of Contents for G4
Page 2: ......
Page 18: ...Technical Manual 1 14 ...
Page 39: ...G4 Multi Channel Weighing Instrument 3 7 ...
Page 104: ...Technical Manual 5 18 ...
Page 158: ...Technical Manual 6 54 ...
Page 178: ...Technical Manual 7 20 ...
Page 186: ...Technical Manual 8 8 ...
Page 196: ......
Page 197: ...G4 Multi Channel Weighing Instrument Appendix 1 ...
Page 198: ...Technical Manual ...
Page 199: ......