Visio-tek Wi-

Fi Microscope User’s Manual 

 

page 25 

8.3.1

 

File 

Selection of a photo or video in the 

Photo or Video folder; click “File” on 

the menu bar or right key of mouse to pop up the 

drop-down menu for operating it. 
 

 

 

Open:

 Opens the selected picture or video to be viewed.  

 

Save as        :

 Save your files into the desired folder and 

file format.  

 

Save all:

 Save all your files in the photo or video folder 

into the desired folder.  

 

Delete:

 Delete the selected image or video. You will be 

prompted to confirm your decision. 

 

Delete All

: Delete all the images or videos in the photo or 

video folder. You will be prompted to confirm your 
decision.

 

 

 

Print

: Print the selected photo 

 

Email       :

 Send the selected images through your default 

email account. 

 

 

8.3.2

 

Setting  

 

Summary of Contents for visio-tek series

Page 1: ...Wi Fi DIGITAL MICROSCOPE USER S MANUAL ...

Page 2: ...Visio tek Wi Fi Microscope User s Manual 2 WARNING READ MANUAL CAREFULLY BEFORE USING THE DEVICE 2017 ...

Page 3: ...i Fi Microscope User s Manual 3 Summary 1 UNPACKING 4 2 PACKAGING CONTENTS 4 3 SYMBOLS 5 4 WARNINGS 7 5 GENERAL GUIDELINES FOR HANDLING 7 6 GENERAL MAINTENANCE 8 7 CLEANING THE DEVICE 8 8 DISPOSAL 9 9 WARRANTY 10 ...

Page 4: ...al and Electronic Inspection QC Education Research and Scientific Analysis Forensics Print inspection Textile inspection Trichology Entomology Botany Mineralogy Collectibles Jewelry and Watch Repair Reading assistance And more Please read this manual carefully before using Visio tek Wi Fi digital microscope 1 UNPACKING Use caution when opening your Visio tek packaging with a sharp objective to avo...

Page 5: ... problem which may present risk to the patient or damage the instrument Cease using the instrument and refer operations manual WARNING Read the instructions SYMBOLS FOR MAINTENANCE TRANSPORT AND ENVIRONMENT High Fragile Keep dry CERTIFICATION SYMBOLS Indicates that the product meets the essential requirements of the EU directive for medical devices 93 42 CEE Indicates the name of the manufacturer ...

Page 6: ...properly disposed of at the end of its life The user is responsible for disposing of the product at a specific collecting point dedicated to electronic and electric devices The product may be returned to the reseller in case of the purchase of a new one The dedicated collection point contributes to an environment policy which encourages the reuse of components from disposed devices Batteries are c...

Page 7: ... storing and operating outside these limits may reduce the life of the product Do not expose this product to water or other liquids If water or other liquids enter the product immediately power off the product Continued use of the product may result in fire or an electrical shock Do not use any detergent or volatile solution as this will damage the camera case painted surfaces and lens To clean th...

Page 8: ...E THE DEVICE 7 CLEANING THE DEVICE IMPORTANT Avoid touching the lens of the device as this can cause permanent damage Store device properly when not in use to keep lens free of dust and particulate Avoid using any other objects or liquids that could easily scratch or damage the surface of the lens or the sensor To clean the body of the device use a slightly dampened soft cloth The device is design...

Page 9: ...g of the product at a specific collecting point dedicated to electronic and electric devices The product may be returned to the reseller in case of the purchase of a new one The dedicated collection point contributes to an environment policy which encourages the reuse of components from disposed devices It has to be disposed of in accordance with local WEEE regulations ...

Page 10: ...tion will be given by the distributor and its distributors if the product is returned during the warranty period In addition any replacement or repair carried out during the warranty time will not prolong the duration of the guarantee The warranty lapses in the following cases The product has been tampered with or the label placed on the USB cable bearing the serial number has been removed damaged...

Page 11: ...ems 14 5 4 Measurement on Windows Systems 15 6 Visio tek on Mac Computers 17 6 1 Installation on Mac Computers 17 6 2 Images on MAC Computers 19 6 3 Calibration on Mac Computers 19 6 4 Measurement on MAC Computers 20 6 4 1 Line Measurement 20 6 4 2 Circle Measurement 21 6 4 3 Area Measurement 21 6 4 4 Circle Measurement 21 6 4 5 Keys 22 7 Working in Wired USB Mode 24 8 USB Visio tek on Windows 24 ...

Page 12: ...ss and to increase or decrease the intensity of light Photo Press to capture the picture of the microscope image Snapshot Button Every time after successful connection of the WiFi microscope you have to enable the Snapshot feature on the App The LED illumination will be off and then light up again The Snapshot only works with the receiver device when the App snapshot feature has been enabled 1 1 C...

Page 13: ...nd click OK 4 Once connected please wait for about 5 seconds to open the Visio tek application to see your images If there is no video display please close and restart the Visio tek app again When the Wi Fi indicator LED flashes the video stream signal should be displayed in the app Video streaming can be broadcasted to many devices but the frame rate of live video will decrease as the number of r...

Page 14: ...rk Name SSID and password in WPA PSK Key and Re Enter and click Next The setting is done now you can re connect the new SSID Wi Fi by entering the new password 3 Visio tek on iPad iPhone 3 1 Installation on iPhone iPad Search Visio tek in the App Store to download and install it Click the icon to display Video Warm up Tips If the live video is blank or slow please restart the Visio tek app again C...

Page 15: ...ts Use the enclosed calibration ruler as to be observed object Bring the image into focus by turning the Focus Magnification Adjustment Wheel Click to pop up the screen on the left Click Calibration click two dots move the dot by clicking in order to draw your desired line then click on the live video to show the following screen 1 Click to select a point and refine the selection by clicking the a...

Page 16: ...llows the measurement of the circumference area and radius of a circle Simply click on any three points on the circle you wish to measure Click the ruler icon and select line Select the two points whose distance is to be measured on the image and click the screen again The measurement will show Click to save the image Please do not adjust the Focus Magnification wheel If the new photo object is no...

Page 17: ...on or measurement operation Photos folder Calibration and measurement Cross guides Reset sketches Setting menu Setting Menu 1 Resolution Setting when changing the resolution please wait until the illumination LED is off and lights up again it takes about 5 seconds Enable the snapshot button Rename the photo Default setting ...

Page 18: ...Visio tek Wi Fi Microscope User s manual page 8 2 Unit Setting 3 Line Setting for editing line size and color 4 Font Setting for editing text size and color ...

Page 19: ...ne the magnification by taking a reading from the scale on the focus dial see illustration 4 Click on the triangle button on the top left of the screen and enter the scale value in the Magnification box 5 Use the enclosed calibration ruler as observed object Click on to show the screen on the left Click to come back to the live video and start calibration Click to select a point and refine the sel...

Page 20: ...e saved on the photo image 4 3 Measurement on Android Tablet Phone Line Allows you to measure the linear distance between two points Simply click and drag to the desired length and click again to finish Angle Allows the measurement of an angle Start at the pivot point and extend out to start measuring an angle Circle Allows the measurement of the circle circumference area and radius Simply click t...

Page 21: ...icon to try again 5 1 Menu Preview live image Take a picture Take Stop Video Take time lapsed pictures Email the selected photos Save the selected photo or video file Or 5 1 1 File Select a photo or video and click File on the menu bar Open Open the selected photo or video to be displayed Save as Save the selected photo or video file to the desired folder and file format Delete Delete the selected...

Page 22: ...Enable the button snapshot The video will temporarily stop please Click Preview again to resume Warm Tips If enabling snapshot prompts a Windows Security Alert as illustrated below in this case Windows 8 You need to check both boxes for Private networks and Public networks and then click Allow access to allow the Snapshot program to communicate on these networks otherwise the button snapshot will ...

Page 23: ...ding to avoid video file size exceeding disk space The number range is 1 99999 Take time elapsed pictures Press the time lapsed button on the active preview window Capture Setting 5 1 4 Help About Software version 5 1 5 Video Processing Please click Preview to resume the live video after completing the video processing discussed below Horizontal Mirror Vertical Mirror Negative Binary Segmentation ...

Page 24: ...Add text into photo Print this photo Delete the selected target Select a target Move the selected target Measurement functions Calibration 5 3 Calibration on Windows Systems To obtain accurate measurement data for each magnification please calibrate before performing measurements 5 To calibrate select a known measuring tool such as a ruler as to be observed object 6 Bring the image of the selected...

Page 25: ...again to finish Point to Line Measurement Allows measurement of a line 90 degrees from a certain line Simply create a line to represent the base by clicking once to start drag and then click again to set the endpoint Branch off from the base line to start measuring the line that is 90 degrees from the base line and make a final click to finish the measurement Continuous Line Measurement Allows mea...

Page 26: ...n arc to measure Three Point Angle Measurement Allows the measurement of an angle Start at the pivot point and extend out to start measuring an angle Four Points Angle Measurement Allows the measurement of an angle by selecting four points Simply select two points from one line segment and another two points from another line segment to complete the angle measurement To measure please enter the ma...

Page 27: ...nstalling Visio tek using the OS X 10 8 or a later version a pop up message will appear as illustrated You need to adjust the following settings Click the Apple icon to pop up the window on the right and click System Preference to open the next window Click on Security Privacy Click Click the lock to make changes ...

Page 28: ...sh the setting Now you may install the Visio tek software Double click the WiFi Visio tek icon after completing installation Click Preview and after a short delay the WiFi main screen will display video it takes about 5 seconds to display the live video if the video image is blank or slow please click the Preview icon once again ...

Page 29: ...alibrate before taking measurements 1 Select a known measurement tool such as a ruler as the target object used for calibration Bring the image of the selected ruler into focus by turning the Focus Magnification Adjustment Wheel and determine the magnification by selecting a scale value on the focus dial Click the icon button to capture an image and then double click the image the following window...

Page 30: ...mages after magnification calibration will be very accurate with a measurement error of under 2 6 4 Measurement on MAC Computers To obtain accurate measurement data for each magnification please calibrate before performing measurements 6 4 1 Line Measurement Select Magnification at the top left of the window Click on the line icon button and a line will display in the video preview window The line...

Page 31: ... Click the reset icon button and a rectangle will display in the video preview window The rectangle can can be moved by selecting its center point and dragging the mouse By selecting the bottom right point of the rectangle and dragging the mouse the area of the rectangle can be changed 6 4 4 Circle Measurement Click the angle icon button and an angle will display in the video preview window The de...

Page 32: ...f a rectangle Measurement Diameter Circle The diameter of a circle measurement allows you to measure the circumference area and radius of a circle Simply click and extend out to the desired diameter Measurement Three Points Angle The three point angle measurement allows the measurement of an angle Start at the pivot point and extend out to start measuring an angle Measurement Four Points Angle The...

Page 33: ...Visio tek Wi Fi Microscope User s Manual page 23 Delete Delete all measurement Redo Redo the previous action ...

Page 34: ...Windows 8 1 System Requirements Windows XP SP2 or later Available USB 2 0 or later port 8 2 Running USB Visio tek Note Before starting the USB Visio tek program please make sure the USB digital microscope has been connected to the PC via a USB line and Power is on After installing USB Visio tek exe double click the USB Visio tek icon on the desktop and the USB Visio tek main screen will show If th...

Page 35: ...wed Save as Save your files into the desired folder and file format Save all Save all your files in the photo or video folder into the desired folder Delete Delete the selected image or video You will be prompted to confirm your decision Delete All Delete all the images or videos in the photo or video folder You will be prompted to confirm your decision Print Print the selected photo Email Send th...

Page 36: ...preview area click Crosshair Scale Line Circle Grid on the drop down menu Snapshot Enable and Snapshot Disable The default is enable snapshot If you notice video delay and wish to improve performance of the video preview please disable the snapshot feature Change Language The language selection allows you to select the USB Visio tek interface language ...

Page 37: ...re projected or displayed per second The number range is 1 30 2 Timer Limit Limits the time of video recording to avoid video file size exceeding disk space The number range is 1 99999 3 Compress Select the video compression format to reduce video size Files are automatically compressed in accordance with your PC system Video quality may vary depending on the compression program used Take time lap...

Page 38: ...0 8 or later QuickTime 7 0 or later Please drag the Visio tek software to the Applications folder to complete installation 9 2 Running USB Visio tek Install the USB Visio tek software from www visio tek net Once the USB Visio tek installation is completed please plug the microscope into an available USB port on your Mac OSX PC and turn the microscope on with the switch on the side The system will ...

Page 39: ... illustrated below 9 3 Setting Note When you are planning to use the microscope in the future be sure to plug it in and turn it on before opening Visio tek Video Resolution Setting Click Controls Format to select your desired resolution as shown on the screen shot below The default resolution is 640X480 If your Visio tek screen freezes on an image this may be because capture resolution was set too...

Page 40: ...elected image thumbnail in the image scroll list to open the image for use of the measurement feature Deleting a Captured image Select the captured image in the image scroll list and press the Del Key on the keyboard to delete it 9 5 Creating Video Click the icon button on the Tool bar of the main screen to start or stop recording Video as illustrated below The Video file name of the time stamp is...

Page 41: ...unning Frequency Range 2 400 2 4835GHz Power Consumption Max 2 5W Frame Rate 10fps 30fps Li ion Battery Continuous Working Time Appx 2 Hours Full Charging Time Appx 4 Hours Power Source DC5 0V 1A Camera Spec Camera Sensor CMOS 1 4 Optical features Exposure Gamma Correction Numerical Aperture White Balance Black Reference Flicker Avoidance Defect Identification Color Saturation Auto Microscope Spec...

Page 42: ...ore clicking OK it takes about 5 seconds Please restart Visio tek app 6 Why does the device feel rather warm after Wi Fi microscope has been working for some time a The Power dissipation of Wi Fi microscope is about 2 5W so the highest internal temperature of the device can reach about 60 C 7 Hong long can the Wi Fi microscope works for after the battery is full charged a It is about 2 hours at 64...