background image

                                               BW-108P AW 

                                                                                                                                           

7- 

    Show Mode 

Press the MENU button up to when the 

  is showing on the display. Press the 

ENTER 

button

  will blinking on the display, use 

DOWN

 and 

UP

 button adjust 

the fade time (0~255), press 

ENTER 

button to store and 

  will blinking on the 

display, use 

DOWN

 and 

UP 

button adjust the wait time (0~255), press 

ENTER

 button 

to store or automatically return to the main functions without any change after 8 

seconds. To go back to the previous functions without any change press the 

MENU

 

button. 

 Blackout Mode 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and

 UP

 button to select the 

 (yes blackout) or 

 (no blackout) mode. Once the mode has been 

selected, press the 

ENTER

 button to setup or automatically return to the main 

functions without any change after 8 seconds. To go back to the previous functions 

without any change press the 

MENU

 button. 

  Manual Mode 

Press the MENU button up to when the 

  is showing on the display. Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 (amber) or 

 (white) or 

 (dimmer) or 

 (strobe). Once 

the selected, press the 

ENTER

 button to confirm and use 

DOWN

 and 

UP

 button to 

adjust the value or automatically return to the main functions without any change 

after 8 seconds. To go back to the previous functions without any change press the 

MENU

 button. 

For strobe, the function corresponds to the value shown below: 

value function 

value  function 

0-7 OFF 

182-189 

Open 

8-15 

Open 

190-231 

Slow close fast open 

16-131 

Strobe from slow to fast 

232-239 

Open 

132-139 Open 

240-247  Random 

strobe 

140-181 

Slow open fast close 

248-255 

Open 

 

                                               BW-108P AW 

                                                                                                                                           

8- 

 Display Inversion 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 (normal) or 

 (inversion) mode. Once the mode has been selected, 

press the 

ENTER 

button to setup or automatically return to the main functions 

without any change after 8 seconds. To go back to the previous functions without any 

change press the 

MENU

 button. 

  Key Board Lock 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

  (lock the key board) or 

  (normal). Once the mode has been selected, 

press the 

ENTER 

button to setup or automatically return to the main functions 

without any change after 8 seconds. To go back to the previous functions without any 

change press the 

MENU

 button. 

 Self-Test 

Press the 

MENU

 button up to when the 

  is blinking on the display. Pressing 

ENTER

 button and the unit will run self-test by built-in program. To go back to the 

previous functions press the 

MENU

 button. 

 LED 

Press the MENU button up to when the 

  is shown on the display. Pressing 

ENTER

 button and the display will blink. Use

 DOWN

 and 

UP

 button to select the 

 (display  on)  or 

 (display off) mode. Once the mode has been 

selected, press 

ENTER

 button to setup or automatically return to the main functions 

without any change after 8 seconds. To go back to the previous functions without any 

change press the 

MENU

 button. 

 Temperature Test 

Press the 

MENU

 button up to when the 

  is blinking on the display. Pressing 

ENTER

 button and the display will show the temperature of the unit. To go back to 

the functions press the

 MENU

 button again. 

 Fixture Hours 

Press the 

MENU

 button up to when the 

  is blinking on the display. Pressing 

Summary of Contents for BW-108P AW

Page 1: ...NO 011 Building Wash BW 108P AW User Guide Advanced LED Technology ...

Page 2: ...BW 108P AW 1 TABLE OF CONTENTS 1 Safety Instruction 2 Technical Specification 3 Main Function 4 How To Control The Unit 5 Troubleshooting 6 Fixture Cleaning ...

Page 3: ...emale Signal cables for linking fixtures available length 1m CCT 1 2m CCT 2 5m CCT 5 or 10m CCT 10 1 Safety Instruction WARNING y Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet y Unpack and check carefully there is no transportation damage before using the unit y Before operating ensure that the volta...

Page 4: ...ket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 20 times of the unit For power supply do not connect in series much more than 4 units use another mains supply for next 4 units BW 108P AW 12 5 Troubleshooting Following are a few common pro...

Page 5: ...ual to 1 6 The end of the DMX 512 system should be terminated to reduce signal errors 7 3 pin XLR connectors are more popular than 5 pin XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin 4 5 Not used BW 108P AW 4 2 Technical Specification y DMX 2 2 channels selectable y LED display with password protection at the...

Page 6: ...TER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup or it will automatically return to the main functions without any change after idling 8 seconds To go back to the functions without any change press the MENU button The main functions are showing below Once you set to after running in show mode fo...

Page 7: ...rol the units you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX512 address Once the address has been selected press and keep ENTER button up to when the display stops blinking or storing automatically 8 sec...

Page 8: ...40 181 Slow open fast close 248 255 Open BW 108P AW 8 Display Inversion Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the normal or inversion mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds To go bac...

Reviews: