pictor M1606
Product Data
25
999.994.256.10-en-1.4
© Vision & Control GmbH 2014
5.1.3 RS232 interface
The device has a RS232 interface for serial communication with a process
control system (PLC, computer). The baud rate is set in the factory to 9.600
kbit/s. It can be adjusted from the software user interface.
The device can be parameterised with vcwin pro via the RS232.
The sending of measured values via the RS232 has to be activated /
parameterised by using of the vcwin pro software.
Parameters RS232 interface
Parameter
Min
Nom
Max
Quantity
1
Baud rate
9.6 kbit/s
115.2 kbit/s
Protocol
depends on the software used
Number of Bits
8
Number of stop-bits
1
Parity
none
Flow control
none
Galvanic isolation
present
Key pad
For operation via the monitor menu the key pad (accessory) can be connected
to the RS232 interface. The power supply of the key pad is done automatically
by the device using the D-sub connector of the connecting cable. For details on
the key pad, please refer to the corresponding data sheet.
Summary of Contents for 4-20-193
Page 62: ......