pictor M1817
Product Data
23
999.994.528.10-en-1.4
© Vision & Control GmbH 2014
5.1 Interfaces
Overview of Interfaces
Video
LAN
Trig.
I/O
LAN / Ethernet interface
PLC and power interface
Trigger, RS232 or Key-Pad interface
Video-Out (SVGA/SXVGA)
Image 4: Overview of interfaces
5.1.1 Digital I/O-Interfaces
The digital I/O interfaces are only available if the device is connected via the
Power/ PLC cable. In this case, the device is connected to the digital inputs
and outputs of a control unit and to the voltage supply.
Parameters Digital inputs
Parameter
Min
Nom
Max
Number of inputs
4
Input voltage (DC)
0 V
24 V
28 V
Input current at 24 V DC
3.5 mA
Input voltage Low (DC)
0 V
Input voltage High (DC)
8 V
28 V
Overvoltage protection
present
Summary of Contents for 4-20-327
Page 62: ......